摘要
通过对廖坊水电站灯泡贯流式机组定子线圈短路烧毁的原因分析和处理过程的介绍,结合灯泡贯流式机组定子线圈检修难度大等特点,提出新的检修处理工艺,为今后灯贯式机组的检修提供新的参考。
This paper introduced reasons and transacting process of a stator coils' bumdown accident that caused by shout circuit fault at Liaofang hydropower station. Author give a new way for maintain stator coils of a bulb flow-type generator for maintaining stator coils is too difficult. So it also gave a new conference to maintain a bulb flow-type generator.
出处
《江西电力》
2007年第4期35-37,49,共4页
Jiangxi Electric Power
关键词
发电机
定子线圈
短路
generator
stator coils
short circuit fault