摘要 以某换热器为例,讨论了管板兼法兰式结构中非线性因素对管板应力的影响,提出了可不做非线性分析,在结构的有限元模型上直接施加螺栓预紧力的简化方法。计算结果表明,该简化方法合理、安全、可靠,为该类结构的强度分析提供了数值依据。 In this paper it was discussed that the effect of nonlinearity factor to the structure of tubesheet extended as a flange, with the example of a specific fixed tubesheet, and introduced that the simplification method of bolt preloading imposed directly on the structural FEA model without nonlinear analysis. The results showed that the simplified method is reasonable, safe, reliable, such as the structural strength analysis providing a numerical basis.
作者 李清娟 赵军
出处 《石化技术》 CAS 2007年第3期28-31,共4页 Petrochemical Industry Technology
关键词 管板兼法兰 换热器 螺栓力 有限元 tubesheet extended as a flange, heat exchanger, bolt force, finite element
  • 相关文献

参考文献3

共引文献147

同被引文献23

  • 1范钦珊.压力容器的应力分析和强度设计[M].北京:原子能出版社,1979..
  • 2国家技术监督局.GB151-1999管壳式换热器[S].北京:中国标准出版社,2000.
  • 3余伟炜,高炳军,陈洪军,等.ANSYS在机械与化工装备中的应用(第二版)[M].北京:中国水利水电出版社,2007.7.
  • 4国家技术监督局.GB16749-1997压力容器波形膨胀节[S].北京:中国标准出版社,1997.
  • 5GB151-1999.管壳式换热器[S].[S].北京:国家质量技术监督局,1999..
  • 6张卫义,王庆生,孙晨.多乙二醇塔再沸器膨胀节应力强度评定[J].石油化工设备,2007,36(5):23-26. 被引量:2
  • 7JB 4732-1995,钢制压力容器--分析设计标准[S].
  • 8Yang Baisong,Geng Haipeng,Lu Mingjian,Yu Lie. Strength analysis of disc rotor heavy-duty gas turbine considering bolt pretension load [C] 2010 IEEE International Conference on Mechatronics and Automation: ICMA 2010,2010:723-728.
  • 9GB150.3-2011,压力容器第3部分设计[S].
  • 10全国压力容器标准化技术委员会.GB150-2011《压力容器》标准释义[M].北京:新华出版社,2012.

引证文献4

二级引证文献30

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部