摘要
对有机硼化合物进行质谱分析,考察不同种类仪器对样品分析的影响,确定使用电喷雾质谱仪效果最好。进一步考察了流动相、正负离子检测模式、离子化试剂及其浓度等因素的影响。实验发现:样品浓度为1×10-4mol/L,使用V(甲醇):V(H2O)=1:1的混合溶剂为流动相,正离子检测,0.1mol/LNa+为离子化试剂条件下可得到满意的谱图。
Characterization for organic boron compounds was studied by mass spectrometry using EI, ESI, MALDI sources and electrospray ionization mass spectrometry (ESI-MS) was eventually choosed for the analy- sis of these compounds. Several factors including mobile phase, detection mode, cationization reagent and compounds concentration, were investigated. The optimal experimental condition of mass spectrometry for the analysis of organic boron compounds was given.
出处
《分析化学》
SCIE
EI
CAS
CSCD
北大核心
2007年第8期1203-1206,共4页
Chinese Journal of Analytical Chemistry
基金
国家自然科学基金(No20035010
20175033)资助项目
关键词
质谱
电喷雾
有机硼化合物
Mass spectrometry, electrospray ionization, organic boron compounds