期刊文献+

3cm以下肺结节螺旋CT下经皮活检的技术评价 被引量:1

Value of pulmonary nodule less than 3cm with cutting needle biopsy under multi-slice CT guidance
在线阅读 下载PDF
导出
摘要 目的:评价多排螺旋CT引导下经皮肺切割针活检直径≤3 cm肺结节的价值。方法:CT引导下经皮肺穿刺活检肺部病灶直径≤3 cm结节101例,病灶用意大利或美国20 G活检针至少穿刺取材。结果:肺结节穿刺准确率达100%,病理证实恶性病灶73例、良性病灶28例,其中结节太小取材少不能定性1例。诊断准确率为99.01%,并发症中气胸发生率13.86%、咯血17.82%,无严重并发症,穿刺针通过肺大泡而没有引起气胸1例。结论:CT引导经皮穿刺直径≤3 cm肺部结节活检的准确性高而并发症较低,可作为肺内3 cm以下孤立性结节灶在临床治疗前病理诊断的首选方法。 Odjective: To evaluate multi - slies spiral CT - guided pereutaneous cutting-needle biopsy in pulmonary nodules less than 3em in diameter.Method: There were 101 pulmonary lesions less than 3em in diameter under CT- guided pereutaneous needle biopsy, Every pulmonary nodule was punctured more than twice with 20 Guage needles made in Italy or U.S.A. Results: The accuracy of punctured through pulmonary nodules was 100 %.There were 73 pulmonary mahgnant tumors and 28 bengin nodules identified by pathological histology and only one without pathological result for small in size in this group.Diagnostic accuracy were 99.01% .The complication included slightly pneumothorax 13.86 %, and hemoptosis in 17.82 % without severe complication. Conclusion: CT- guided pereutaneous needle biopsy in solitary pulmonary nodules ≤3 cm in diameter is best method with high accuracy and low complication for pathological diagnosis before clinic treatment.
出处 《医疗装备》 2007年第8期7-9,共3页 Medical Equipment
关键词 3cm 肺结节 CT 3cm pulmonary nodule CT
  • 相关文献

参考文献8

二级参考文献45

  • 1[1]Westcott J L, Rao N, Colley D P. Transthoracic needle biopsy of small pulmonary nodules[J]. Radiology, 1997, 202(1): 97-103.
  • 2[2]Zavala D C. Diagnostic fiberoptic bronchoscopy: technicques and results of biopsy in600 patients[J]. Chest, 1975, 68(1): 12- 19.
  • 3[4]Yankelevitz D F, Henschke C I, Koizumi J, et al. CT-guided transthoracicneedle biopsy following indeterminate fiberoptic bronchoscopy in solitary pulmonary nodules[J]. Clin Imaging, 1998, 22(1): 7 - 10.
  • 4[5]Klein J S, Salomon G, Stewart E A. Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: results in 122 patients [J]. Radiology, 1996, 198(3): 715-722.
  • 5[6]Moulton J S, Moore PT. Coaxial percutaneous biopsy technique with automated biopsy devices: value in improving accuracy and negative predictive value[J]. Radiology, 1993, 186(12): 515-522.
  • 6[10]Laurent F, Latrabe V, Vergier B, et al. CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20mm: results with an automated 20-gauge coaxial cutting needle[J]. Clin Radiol, 2000, 55(4): 281-286.
  • 7[1]Charatan F. US panel finds insufficient evidence to support mammorgraphy. BM J, 2002, 324:255
  • 8[2]Kolata G. Export panel cites doubts on mammnogram's worth.New York Times, 2002, Al6
  • 9[3]Feuer E J, Merrill RM, Hankey BF. Interpreting trends in prostate cancer: Part Ⅱ . Cause of death misclassification and the recent rise and fall in prostate cancer mortality. Cancer Surveillance Series. J Natl Cancer Inst, 1999, 91:1025
  • 10[4]Hankey BF, Feuer EJ, Clegg LX, et al. Interpreting trends in prostate cancer: part I. Evidence of the effects of screening in recent prostate cancer incidence, mortality, and survival rates.Cancer Surveillance Series. J Natl Cancer Inst, 1999, 91:1017