根据Kern方程,推导得到了冷却水压差和离心式制冷机制冷量的关系,可用于制冷机的运行管理。
Based on the Kern equation, establishes the relationship between the pressure difference of cooling water and refrigerating output of centrifugal water chillers, which is helpful for the management of refrigerating machines.