摘要 该实施规程提出应急和备用电源设备的使用、电源类型、设计和维护。其中第三章概述了社会对应急和备用电源设备的需求以及应急和备用电源设备的配置。第九章罗列了特殊产业对这些电源的不同需求。第四章和第五章论述了这些电源的选用问题。第六章就电源设备和开关装置在系统发生故障时的保护,提出了推荐的应对措施。第七章对设备的接地提出了推荐的设计要求。第十章对满足可靠性目标提出了推荐的设计要求。第八章提出了推荐的维护实施规程。 This Recommended Practice addresses the uses, power sources, design, and maintenance of emergency and standby power systems. Chapter 3 is a general discussion of needs and the configuration of emergency and standby systems. Chapter 9 lists the power needs for specific industries. Chapters 4 and 5 deal with selection of power sources. Chapter 6 provides recommendations for protecting both power sources and switching equipment during fault conditions. Chapter 7 provides recommendations for design of system grounding, and Chapter 10 provides recommendations for designing to reliability objectives. Chapter 8 provides recommended maintenance practices.
出处 《电源技术应用》 2007年第6期83-96,共14页 Power Supply Technologles and Applications
关键词 蓄电池 应急发电机 应急电源 应急设备 应急设备的设计 发动机驱动型发电机 备用电源 备用设备 储能系统 转换开关 不间断电源(UPS) 不间断电源用蓄电池 batteries emergency generators emergency power emergency system emergency system design enginegenerators standby power standby system stored energy systems transfer switch uninterruptible power supplies UPS UPS batteries