期刊文献+

Application of correlation techniques in the analysis of corpus cavernosum electromyographic signals 被引量:2

Application of correlation techniques in the analysis of corpus cavernosum electromyographic signals
暂未订购
导出
摘要 Aim: To establish an objective, easy-to-use and comprehensive method to analyze corpus cavernosum electromyo- graphic signals (CC-potentials). Methods: CC-potentials were recorded during flaccidity in 23 young healthy volunteers, with surface electrodes placed on the penile shaft bilaterally. Based on the correlation function of Matlab software, an application program for the analysis of CC-potentials was developed. Individual CC-potentials and their autocorrelation function were evaluated, yielding parameters amplitude (A), duration (D), and dominant frequency (DF). The crosscorrelation function of both longitudinal and bilateral pairs of adjacent electrodes was calculated to assess the similar- ity and mutual delay of CC-potentials recorded simultaneously from different parts of the CC. The parameters derived were squared maximum cross-correlation coefficient (Rmax) and delay (τ). Based on the absolute value of τ and the corresponding inter-electrode distance, propagation velocity (PV) was calculated. Results. The values of the parameters were determined automatically. No significant difference related to the locations of the electrodes for parameters A, D, and DF was detected. The cross-correlation showed that both longitudinal and bilateral CC-potential pairs had highly similar waveforms (the absolute values of Rmax were 0.80 ± 0.05 and 0.87 ± 0.06, respectively). PV of longitudinal pairs was estimated as 6.15 ± 3.98 cm/s. Conclusion: The application program for correlation analysis of CC-potentials is a comprehensive and versatile method to analyze corpus cavernosum electromyographic recordings. Its objectiveness makes multi-center application possible. Aim: To establish an objective, easy-to-use and comprehensive method to analyze corpus cavernosum electromyo- graphic signals (CC-potentials). Methods: CC-potentials were recorded during flaccidity in 23 young healthy volunteers, with surface electrodes placed on the penile shaft bilaterally. Based on the correlation function of Matlab software, an application program for the analysis of CC-potentials was developed. Individual CC-potentials and their autocorrelation function were evaluated, yielding parameters amplitude (A), duration (D), and dominant frequency (DF). The crosscorrelation function of both longitudinal and bilateral pairs of adjacent electrodes was calculated to assess the similar- ity and mutual delay of CC-potentials recorded simultaneously from different parts of the CC. The parameters derived were squared maximum cross-correlation coefficient (Rmax) and delay (τ). Based on the absolute value of τ and the corresponding inter-electrode distance, propagation velocity (PV) was calculated. Results. The values of the parameters were determined automatically. No significant difference related to the locations of the electrodes for parameters A, D, and DF was detected. The cross-correlation showed that both longitudinal and bilateral CC-potential pairs had highly similar waveforms (the absolute values of Rmax were 0.80 ± 0.05 and 0.87 ± 0.06, respectively). PV of longitudinal pairs was estimated as 6.15 ± 3.98 cm/s. Conclusion: The application program for correlation analysis of CC-potentials is a comprehensive and versatile method to analyze corpus cavernosum electromyographic recordings. Its objectiveness makes multi-center application possible.
出处 《Asian Journal of Andrology》 SCIE CAS CSCD 2007年第3期369-376,共8页 亚洲男性学杂志(英文版)
关键词 corpus cavernosum corpus cavernosum electromyography ELECTROPHYSIOLOGY erectile dysfunction smooth muscle corpus cavernosum corpus cavernosum electromyography electrophysiology erectile dysfunction smooth muscle
  • 相关文献

同被引文献13

引证文献2

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部