摘要 随着天然气的大量开采,天然气市场供需双方对计量准确度要求越来越高,输气系统的输差问题就越发突出起来。目前国内天然气市场以供方计量为准,由于诸多因素的影响供需双方交接差较大,不能反映实际,常引起计量纠纷。本文针对气田投产初期输差较大的问题,从仪表安装、组分变化、程序参数设置及使用条件变化等几个方面分析了输差问题产生的原因,并提出了问题的解决方法及建议。 As the large exploitation of gas, the both sides of natural gas supply and demanding paid more and more attention to the accuracy of measurement, so the transportation discrepancy problem about the system of gas transportation become more serious. Recently, the domestic gas market measurement is standard by the suppliers, but the various kinds of influence changed the volume of business, which often cause the dispute of measurement. This article is aimed atthe big problem of the transportation discrepancy in the initial stage of the gas field commissioning , analyzing the reason of the problem of the transportation discrepancy by the installing of meter,the change of composing ,the change of program parameter establishing and using condition , and so on. It also give some suggestions and resolution for those problems.
出处 《石油化工应用》 CAS 2007年第2期53-56,共4页 Petrochemical Industry Application
关键词 天然气 计量 输差 分析 natural gas measurement transportation discrepancy analyse
  • 相关文献

参考文献2

  • 1用标准孔板流量计测量天然气流量[S],中华人民共和国石油天然气行业标准SY/T6143—2004,国家发展和改革委员会发布.
  • 2梁光川,袁宗明,蒲爱华,谢英,蒋长春,陈仲科,毛洪光.天然气输差问题分析与研究[J].天然气工业,1999,19(5):70-75. 被引量:19

二级参考文献3

  • 1中国石油天然气总公司发布,中华人民共和国石油天然气行业标准SY/T6143-1996,1996年
  • 2姚光镇,输气管道设计与管理,1991年
  • 3董峰,徐苓安,杨克家,李砚青,俞京,周国志.脉动流条件下煤气计量的误差估计[J].煤气与热力,1998(1):27-31. 被引量:5