期刊文献+

Carisolv^(TM)去龋对牙本质黏结强度的影响 被引量:5

Infuence of Carisolv^(TM) on resin adhesion for two different adhesive systems to caries-affected dentine
暂未订购
导出
摘要 目的:评价化学机械去龋系统CarisolvTM对龋病内层牙本质黏结强度的影响。方法:40个人离体中龋磨牙,随机分成2组,分别用慢速手机球钻和CarisolvTM去龋,然后用黏结剂Prime&Bond NT或Contax黏结,复合树脂(Chrisma A2)充填。制备测试微拉伸黏结强度的龋病内层牙本质条状试件,在万能材料实验机上测定黏结强度。结果:CarisolvTM去龋,用两种黏结剂黏结后牙本质的黏结强度为,Prime&Bond NT:(22.86±3.42)MPa;Contax:(28.15±5.39)MPa。慢速手机球钻去龋,两种黏结剂黏结后的牙本质黏结强度为,Prime&Bond NT:(22.23±4.26)MPa;Contax:(26.68±6.41)MPa。结论:CarisolvTM去龋对牙本质黏结强度无显著影响。 AIM : To evaluate the influence of CarisolvTM ( Medi Team) for resin adhesion. METHODS : 40 extracted permanent teeth with coronal carious lesions extending into mid - dentin were used. Caries were removed with Carisolv or rotating round burs. After clinical caries excavation, the occlusal cavities in each experimental group were restored with either Prime&Bond NT or Contax, then filled with Chrisma resin (Kulzer) . Matchstick - shaped samples through the bond interfaces between composite resin and caries - affected dentine were sectioned and microtensile bond strengths recorded. RESULTS: The microtensile bond strengths between resins and dentin with Carisolv caries removal and round burs caries removal were as follows: Carisolv^TM groups: Prime&Bond NT: (22. 86 ± 3.42 ) Mpa; Contax: (28.15 ± 5.39) Mpa. Round burs groups : Prime&Bond NT: ( 22.23± 4. 26 ) Mpa; Contax : ( 26.68± 6.41 ) Mpa. CONCLUSIONS : From the data generated by this study it could be concluded that the use of Carisolv^TM gel excavation did not compromise bond strengths to caries - affected dentine in either group tested.
出处 《牙体牙髓牙周病学杂志》 CAS 2007年第2期82-85,共4页 Chinese Journal of Conservative Dentistry
关键词 微拉仲黏结强度 龋病内层牙本质 伢典 micro - tensile bond strength caries - affected dentine Carisolv^TM
  • 相关文献

参考文献5

  • 1张勇,储冰峰,刘洪臣.Carisolv(伢典)微创化学机械去龋法治疗老年人龋齿的临床研究[J].中华老年口腔医学杂志,2005,3(2):81-83. 被引量:26
  • 2Hosoya Y,Kawashita Y,Marshall GW,et al.Infuence of Carisolv for resin adhesion to sound human primary dentin and young permanent dentin[J].J Dent,2001,29(3),163-171
  • 3洪法廉,李颖超,史俊南,杨连甲,金岩,王志良,李耀君,刘守智.牙本质二层龋的探讨[J].口腔医学,1990,10(3):117-119. 被引量:13
  • 4Cederlund A,Lindskog S,Blomlof J.Effect of a chemo-mechanical caries removal system(Carisolv)on dentin topography of non-carious dentin[J].Acta Odontol Scand,1999,57(4):185-189
  • 5Banerjee A,Kidd EAM,Watson TF.Scanning electron microscopic observations of human dentine after mechanical caries excavation[J].J Dent,2000,28(3),179-186

二级参考文献15

  • 1刘洪臣.老年口腔医学进展[J].中华老年口腔医学杂志,2003,1(1):2-4. 被引量:253
  • 2储冰峰,刘洪臣,王向.根龋封闭治疗后的细菌学和病理学研究[J].中华老年口腔医学杂志,2003,1(1):15-18. 被引量:16
  • 3魏静,徐斌.老年人牙根面龋治疗的临床进展[J].中华老年口腔医学杂志,2005,3(1):54-55. 被引量:5
  • 4[5]Banerjee A,Watson TF,Kidd E AM.Dentine caries excava tion a review of current clinical techniques [J].Br DentJ,2000,188:476~482
  • 5[6]D .Ericson,M.Zimmerman,H.Raber,et al.Clinical Evalu ation of Efficacy and Safety of a New Method for ChemoMechanical Removal of Caries[J].Caries Res, 1999,33(3):171~177
  • 6[7]G.Ansari,J.A.Beeley,D.E.Fung.Chemomechanical caries removal in primary teeth in a group of anxious children[J].J Oral Rehabi,2003,30:773~779
  • 7[8]Hanning M.Effect of Carisolv solution on sound, deminer alized and denatured dentin-an ultrastructural investigation [J].Clin Oral Invest 1999,3:155~159
  • 8[9]Haak R,Wicht M J,Noack MJ.Does chemomechanical caries removal affect dentine adhesion [J].Eur J Oral Sci,2000,108:449~455
  • 9[11]S.Fure P.Lingstrom,D.Birkhed. Evaluation of Carisolv for the Chemo-Mechanical Removal of Primary Root Caries in vivo[J].Caries Res,2000,34(3):275~280
  • 10[14]A.R.Yazici,P.Atilla,G.Ozgunaltay.In vitro comparison of the efficacy of Carisolv and conventional rotary instru ment in caries removal[J].J Oral Rehabil2003,30:1177~1182

共引文献37

同被引文献31

引证文献5

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部