期刊文献+

Rapid development of late stent malappositon and coronary aneurysm following implantation of a paclitaxel-eluting coronary stent 被引量:5

Rapid development of late stent malappositon and coronary aneurysm following implantation of a paclitaxel-eluting coronary stent
原文传递
导出
摘要 Late stent malapposition (LSM), an unusual intravascular ultrasound (IVUS) finding at follow-up,has been reported to be more common alter drug-eluting stem (DES) implantation than after bare metal stent (BMS) implantation. However, there has been no clear elucidation of time course and mechanism. We reported a case who developed LSM and coronary aneurysm very early after paclitaxel-eluting stent (PES) implantation. A review of the literature reveals no previous report describing rapid development of LSM and coronary aneurysm after PES implantation. Late stent malapposition (LSM), an unusual intravascular ultrasound (IVUS) finding at follow-up,has been reported to be more common alter drug-eluting stem (DES) implantation than after bare metal stent (BMS) implantation. However, there has been no clear elucidation of time course and mechanism. We reported a case who developed LSM and coronary aneurysm very early after paclitaxel-eluting stent (PES) implantation. A review of the literature reveals no previous report describing rapid development of LSM and coronary aneurysm after PES implantation.
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2007年第7期614-616,共3页 中华医学杂志(英文版)
基金 the Young Scientist Fund from Shanghai Municipal Health Bureau
关键词 late stent malapposition drug-eluting stent vessel remodeling late stent malapposition drug-eluting stent vessel remodeling
  • 相关文献

参考文献10

  • 1Ako,J,Morino,Y,Hassan,A,Sonoda,S,Yock,PG,Leon,MB,Moses,JW,Bonneau,HN,Fizgerald,PJ.Late incomplete stent apposition after sirolimus-eluting stent implantation: a serial intravascular ultrasound analysis[].Journal of the American College of Cardiology.2005
  • 2Hong MK,Mintz GS,Lee CW,Park DW,Park KM,Lee BK, et al.Late stent malapposition after drug-eluting stent implantation: an intravascular ultrasound analysis with long-term follow-up[].Circulation.2006
  • 3Mintz,GS,Weissman,NJ,Dawkins,K.Frequency, predictors, and clinical outcomes of late-acquired incomplete stent apposition in patients treated with Taxus stents a volumetric intravascular ultrasound meta-analysis from the TAXUS IV, V, and VI trials (abstr)[].Journal of the American College of Cardiology.2006
  • 4KOZUMA K,COSTA MA,SABATE M,SERRANO P,VAN DER GIESSEN WJ,LIGTHART JM,ET AL.LATE STENT MALAPPOSITION OCCURRING AFTER INTRACORONARY Β-IRRADIATION DETECTED BY INTRAVASCULAR ULTRASOUND[].Journal of Invasive Cardiology.1999
  • 5MINTZ GS,WEISSMAN NJ,FITZGERALD PJ.INTRAVASCULAR ULTRASOUND ASSESSMENT OF THE MECHANISMS AND RESULTS OF BRACHYTHERAPY[].Circulation.2001
  • 6HONG MK,MINTZ GS,LEE CW,KIM YH,LEE SW,SONG JM,ET AL.INCIDENCE, MECHANISM, PREDICTORS, AND LONG-TERM PROGNOSIS OF LATE STENT MALAPPOSITION AFTER BARE-METAL STENT IMPLANTATION[].Circulation.2004
  • 7SERRUYS PW,DEGERTEKIN M,TANABE K,ABIZAID A,SOUSA JE,COLOMBO A,ET AL.INTRAVASCULAR ULTRASOUND FINDINGS IN THE MULTICENTER, RANDOMIZED, DOUBLE-BLIND RAVEL (RANDOMIZED STUDY WITH THE SIROLIMUS-ELUTING VELOCITY BALLOON-EXPANDABLE STENT IN THE TREATMENT OF PATIENTS WITH DE NOVO NATIVE CORONARY ARTERY LESIONS) TRIAL[].Circulation.2002
  • 8KAUL U,GUPTA R K,KACHRU R.Large coro-nary artery aneurysms following siroli mus eluting stent i mplantation[].Heart.2005
  • 9Gupta RK,Sapra R,Kaul U.Early aneurysm formation after drug-eluting stent implantation:an unusual life-threatening complication[].Journal of Invasive Cardiology.2006
  • 10DEGERTEKIN M,REGAR E,TANABE K,LEMOS P,LEE CH,SMITS P,ET AL.EVALUATION OF CORONARY REMODELING AFTER SIROLIMUS-ELUTING STENT IMPLANTATION BY SERIAL THREE-DIMENSIONAL INTRAVASCULAR ULTRASOUND[].The American Journal of Cardiology.2003

同被引文献9