期刊文献+

基于GPRS的电力监控终端网络接入方案 被引量:5

Design of Electric Power Monitoring Unit Accessing Internet Based on GPRS
在线阅读 下载PDF
导出
摘要 针对目前无线通信技术在电力监控系统中的应用,研究了一种通过GPRS网络将电力监控终端接入互联网的技术方案。该方案利用GPRS无线模块与GPRS网络间的无线信道作为物理层接口,在此之上通过PPP协议实现数据链路层,最后采用uIP软件协议栈实现精简的TCP/IP协议作为网络层和传输层。在应用层采用了自定义规约。由于协议各层次都是纯软件实现,因此本方案具有成本低廉、配置灵活的特点,并且在现场使用,效果良好。 Due to the application of wireless communication technology in the electric power monitoring system, the method that power monitoring unit accessing Internet based on GPRS is presented. The wireless channels between the GPRS wireless module and GPRS network are as the interface of physical layer, the PPP is used to data link layer. Also the uIP protocol instead of the complicated TCP/IP is used to implement the network layer and the transport layer. The user-defined protocol is used to the application layer. Since the protocols are implemented by software, it is low cost and flexible configuration. And the power monitoring unit is used in good working order.
出处 《测控技术》 CSCD 2007年第3期56-58,共3页 Measurement & Control Technology
关键词 GPRS 电力监控 PPP协议 GPRS power monitoring point-to-point protocol
  • 相关文献

参考文献5

二级参考文献18

  • 1吴兵,马宝甫,刘文江.GPRS网络应用系统中的协议转换[J].单片机与嵌入式系统应用,2004,4(6):20-22. 被引量:2
  • 2[1]RTL8019AS Realtek Full-Duplex Ethernet Controller with Plug and Play Function Specification, 2002
  • 3[2]ATMEL AT89C55WD datasheet, 2001
  • 4[3]Adam Dunkels. uIP 0.9 reference manual, 2003
  • 5[4]Adam Dunkels. uIP - A free Small TCP/IP Stack, 2002
  • 6[6]王罡,林立志编著.基于Windows的TCP/IP编程.北京:清华大学出版社,2000
  • 7The Point to Point[s]. RFC1661, 1994.
  • 8PPP in HDLC Like Framing[s], RFC 1662, 1994.
  • 9The PPP Internet Protocol Control Protocol, RFC 1334, 1992.
  • 10W. Simpson,The Point-to-Point Protocol, http://www.faqs.org/rfcs/rfc1661.html,1994