摘要 目的应用磁共振水成像术(MRH)衍生的磁共振涎管成像术(MRS)对涎腺病变导管系统变化进行观察。方法对33例涎腺病变患者进行MRS,采用4种序列显示腮腺导管系统,然后给患者含服维生素C,分别于3min和10min后再次扫描,比较腮腺导管系统的显示效果。结果IR-FSE序列较FSE腮腺导管显示效果明显提高(P<0.05),服药后腮腺导管显示效果有一定的提高(P>0.05)。结论MRS对腮腺导管系统显像良好,具有简单、无创、安全等优点,能提供全面、立体的腮腺病变信息。 Objective To observe the changes of the disorder of salivary gland ducts with magnetic resonance sialngraphy(MRS) derived from magnetic resonance hydrography(MRH). Methods Thirty-three cases of salivary gland disorders received MRS, using four sequences, then 200 mg Vitamin C pills were administered.While they were kept in the mouth, MR imaging performed 3 and 10 mira later, respectively and the images of parotid gland ducts were compared. Results IR-FES sequence was superior to conventional FSE sequence in demonstrating the parotid gland duct and its branches(P 〈0.05). The image quality improved after Vitamin C pills administratian(P 〉0.05). Conclusions Compared with the common X-ray photography, magnetic resonance and MR sialography axe simple, non-injury, and safe 3-D, and more information can be obtained through MRS. MR sialography is a good alternative for imaging parotid gland ducts and important in formulating and operating program.
出处 《口腔医学》 CAS 2007年第2期82-83,94,共3页 Stomatology
关键词 涎腺 疾病 磁共振水成像 腮腺导管 salivary gland disorder magnetic resonance imaging sialography parotid gland ducts hydrography
  • 相关文献

参考文献6

  • 1W.Golder,H.Daschner,朱声荣.涎腺造影术——当今评价[J].放射学实践,1993,8(3):105-109. 被引量:4
  • 2Minerva B,Francis M,Christooph D,et al.Sialolithiasis and salivary ductal stenosis:diagnostic accuracy of MR sialography with a three-dimensional extended-phase conjugate-symmetry rapid spin-echo sequence[J].Radiol,2000,217(2):347-58.
  • 3朱声荣,王秀丽,邵乐南,陈卫民,陈新明,吴慧华.腮腺肿瘤及瘤旁腺泡p16、p21和DNA定量研究[J].中华口腔医学杂志,2001,36(5):361-363. 被引量:9
  • 4Verghese JC,Thornton F,Lucey BC,et al.A prospective comparative study of MR sialography and conventional sialography of salivery duct disease[J].ASR,1999,913(6):1497-1503.
  • 5卢延,张雪哲,洪闻,陆立,王武.MR涎管造影初探[J].中华放射学杂志,1997,31(11):744-747. 被引量:15
  • 6Ohbayashi N,Yamada I,Yoshino N,et al.Sjogren syndrome comprison of assessments with MR sialography and convertional sialography[J].Radiol,1998,209(3):683-688.

二级参考文献2

共引文献25

同被引文献22

  • 1史瑞华,漆剑频,冯定义,邹明丽,胡军武,朱文珍,夏黎明,王承缘.MR涎管造影临床研究及应用[J].中华放射学杂志,2004,38(8):838-842. 被引量:13
  • 2陶学金,冯定义,汤国雄,陈卫民,朱声荣.腮腺导管磁共振成像研究[J].中华口腔医学杂志,2004,39(6):467-470. 被引量:5
  • 3胡军武,冯定义,史瑞华,夏黎明,王承缘.短时反转恢复序列在MR涎管造影中的对比研究[J].临床口腔医学杂志,2005,21(5):297-299. 被引量:2
  • 4邱蔚六.口腔颌面外科学[M].第五版.北京:人民卫生出版社,2004,195
  • 5Lomas DJ, Carroll NR, Johnson G, et al. MR sialography: Work in progress[J]. Radiology, 1996,200(1):129-133.
  • 6Murakami R, Baba Y, Nishimura R, et al. MR Sialography Using Half-fourier acquisition single-shot turbo spin-echo (HASTE)Sequences [J].AJNR Am J Neuroradiol, 1998,19 (5):959-961.
  • 7Morimoto Y, Tanaka T, Yoshioka I, et al. Virtual endoscopic view of salivary gland ducts using MR sialography data from three dimension fast asymmetric spin-echo (3D-FASE)sequences:a preliminary study [J]. Oral Dis, 2002,8(5):268-274.
  • 8Morimoto Y, Tanaka T, Tominaga K, et al. Clinical application of magnetic resonance sialographic 3- dimensional reconstruction imaging and magnetic resonance virtual endoscopy for salivary gland duct analysis[J]. Oral Maxillofac Surg, 2004,62(10):1237-1245.
  • 9Shojaku H, Shojaku H, Shimizu M, et al. MR Sialographie evaluation of sialectasia of stensen's duct:comparison with X-ray sialography and uhrasonography [J]. Radiat Med, 2000,18(2):143-145.
  • 10Becker M, Marchal F, Becker CD, et al. Sialolithiasis and salivary ductal stenosis:diagnostic accuracy of MR sialography with a three-dimensional extended-phase conjugate-symmetry rapid spin-echo sequence [J]. Radiology, 2000,217(2):347-358.