期刊文献+

椎弓根钉固定结合注射性硫酸钙椎体成形术治疗胸腰椎骨折 被引量:20

Treatment of thoracolumbar fractures with pedicle screw fixation and calcium sulfate cement vertebroplasty
原文传递
导出
摘要 目的探讨椎弓根钉复位固定结合注射性硫酸钙(CSC)椎体成形术治疗胸腰椎骨折的方法和疗效。方法自2004年6月~2005年6月,对21例胸腰椎骨折采用椎弓根钉复位、固定后,再通过椎弓根将伤椎塌陷终板骨块推顶复位,灌注可注射性CSC行椎体成形术的治疗方法。术后随访并评估此方法的临床疗效。结果平均每个椎体灌注CSC5.5mL;2例术中发生椎管内渗漏,漏出呈液态,术后患者无神经症状加重;根据影像学评估,随访时测得Cobb角、椎体前缘高度比值[分别为6.7°±8.1°,(76.7±6.9)%]与术前[分别为21.6°±6.5°,(44.9±2.1)%]比较,差异有统计学意义(P〈0.05),而与术后即刻[分别为6.2°±8.9°,(78.3±7.7)%]比较,差异无统计学意义(P〉0.05)。经8~14个月(平均11.5个月)随访,无椎弓根钉失败病例。结论椎弓根钉复位、固定后采用可注射性CSC行椎体成形术操作简单,无椎管内占位及栓塞等并发症发生,安全性高,可有效恢复椎体力学性能,减少单纯椎弓根钉固定后断钉及椎体高度再丢失等并发症。 Objective To investigate surgical techniques and clinical results of pedicle screw fixation and calcium sulfate cement (CSC) vertebroplasty in treatment of thoracolumbar fractures. Methods From June 2004 to June 2005, 21 patients with thoracolumhar fracture were treated with short-segment pedicle screw fixation, reduction of the endplate and reinforcement of the injured vertebra with injectable CSC. Results CSC leakage occurred in 2 patients who experienced no worsening neurologic symptoms after surgery. The average CSC filling volume was 5.5 mL for one vertebra. There were significant differences in the kyphotic Cobb angle and ratio of anterior vertebral height between their postoperative and preoperative radiological measurements. Follow-up showed no significant deformity in the angle and ratio after surgery. There was no pedicle screw failure in the follow-up period of 8 months to 14 months. Conclusions CSC vertebroplasty combined with pedicle screw fixation is simple and safe, and unlikely to result in CSC leakage, embolism or other complications like pedicle screw failure and loss of vertebral height. After CSC vertebroplasty, vertebral mechanical performance can be restored effectively.
出处 《中华创伤骨科杂志》 CAS CSCD 2007年第3期225-228,共4页 Chinese Journal of Orthopaedic Trauma
基金 江苏省卫生厅“135工程”重点学科开放课题(K0618)
关键词 胸椎 腰椎 骨折 椎体成形术 硫酸钙 并发症 Thoracic spine Lumbar spine Fractures Vertebroplasty Calcium sulfate cement (CSC) Complications
  • 相关文献

参考文献17

  • 1杨惠林,唐天驷,朱国良,洪天禄,许立,陈荣发,郑祖根.胸腰椎骨折经椎弓根内固定治疗中的失误和并发症的分析[J].中华骨科杂志,1996,16(6):356-359. 被引量:155
  • 2Alanay A, Acaroglu E, Yazici M, et al.Short-segment pedicle instrumentation of thoracolumbar burst fractures: does transpedicular intracorporeal grafting prevent early failure? Spine,2001,26:213-217.
  • 3Boeree NB, Harley J, Jockson BK, et al. Fixation of spinal fractures:can failure be predicted? British Scoliosis Society Annual Meeting,Bristol, 1994:58-61.
  • 4Speth MJ, Oner FC, Kadic MA, et al. Recurrent kyphosis after posterior stabilization of thoracolumbar fractures. 24 cases treated with a dick internal fixator followed for 1.5-4 years. Acta Orthop Scand,1995,66: 406-410.
  • 5张贵林,荣国威,丁占云,姜春岩,吴宏华.脊柱胸腰段骨折术后椎弓根螺钉断裂及弯曲松动的原因分析[J].中华骨科杂志,2000,20(8):470-472. 被引量:283
  • 6McAfee PC, Bohlman HH. Complications following Harrington instrumentation for fractures of the thoracolumbar spine. J Bone Joint Surg(Am), 1985, 67: 672-686.
  • 7刘团江,郝定均,王晓东,付亚辉.胸腰段骨折椎弓根钉复位固定术后骨缺损的CT研究[J].中国矫形外科杂志,2003,11(10):706-707. 被引量:107
  • 8McCormack T, Karaikovic E, Gainnes RW. The load sharing classification of spine fracture. Spine, 1994, 19: 1741-1744.
  • 9Cho DY, Lee WY, Sheu PC. Treatment of thoracolumbar burst fractures with polymethyl methacrylate vertebroplasty and short-segment pedicle screw fixation. Neurosurgery, 2003, 53:1354-1361.
  • 10Mermelstein LE, McLain RF, Yerby SA. Reinforcement of thoracolumbar burst fractures with calcium phosphate cement: a biomechanical study. Spine, 1998, 23: 664-670.

二级参考文献44

  • 1杨惠林,唐天驷,朱国良,洪天禄,许立,陈荣发,郑祖根.胸腰椎骨折经椎弓根内固定治疗中的失误和并发症的分析[J].中华骨科杂志,1996,16(6):356-359. 被引量:155
  • 2Weidenbanx M, Farcy JPC. Surgical management of thoracic and lumbar burst fractures. In: Bridwell KH, Dewald RL, eds. The text book of spinal surgery. 2nd ed. Philadelphia(NY) : Lippincott - Raven Publishers,1997. 1839- 1880.
  • 3McLain RF, Sparling E, Benson DR. Early failure of short- segment pedicle instrumentation for thoracolumbar fractures. A preliminary report.J Bone Joint Surg (Am), 1993, 75:162 - 167.
  • 4Alanay A, Acaroglu E, Yazici M, et al. Short- segment pedicle instrumentation of thoracolumbar burst fractures: does transpedicular intracorporeal grafting prevent early failure? Spine, 2001, 26:213 -217.
  • 5Knop C, Fabian HF, Bastian L, et al. Late results of thoracolumbar fractures after posterior instrumentation and transpedicular bone grafting.Spine, 2001, 26: 88-99.
  • 6Cotton A, Boutry N, Cortet B, et al. Pemutaneous vertebroplasty: state of the art. Radiographics, 1998, 18:311-320.
  • 7Mermelstein LE, McLain RF, Yerby SA. Reinforcement of thoracolumbar burst fractures with calcium phosphate cement. Spine, 1998, 23:664 -670.
  • 8Belkoff SM, Mathis JM, Erbe EM, et al. Biomechanical evaluation of a new bone cement for use in vertebroplasty. Spine, 20(10, 25:1061 -1064.
  • 9Deramond H, Depriester C, Galibert P, et al. Percutaneous vertebroplasty with polymethylmethacrylate. Technique, indications and results.Radiol Clin, 1998, 36 : 533 - 546.
  • 10Cotton A, Dewatre F, Cortet B, et al. Percutaneous vertebroplasty for osteolytic metastases and mydoraa: effects of the percentage of lesion filling and the leakage of methyl methacrylate at clinical follow- up.Radiology, 1996, 200:525-530.

共引文献634

同被引文献258

引证文献20

二级引证文献224

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部