期刊文献+

64层螺旋CT与磁共振成像评价左心功能的比较研究 被引量:24

Assessment of left ventricular myocardial function using 64-slice CT: comparison with MRI
暂未订购
导出
摘要 目的以磁共振为对照,应用64层螺旋CT(MSCT)定量评价左心功能,探讨MSCT成像技术和屏气法MRI电影技术心功能评价指标的相关性及MSCT在冠心病左心功能评价中的应用价值。方法临床拟诊冠心病的患者20例,均自愿参加。全部病例均行心脏MSCT和MRI检查。结果MSCT和MRI两种方法的心功能指标无显著性差异,两种方法的心功能指标舒张末期容积(EDV)、收缩末期容积(ESV)、每搏输出量(SV)、左室射血分数(EF)、心肌质量(MM)相关性高,r值=0.72~0.92。MSCT所测EDV、ESV、SV和MM值较MRI偏大,MSCT所测EF值较MRI偏小。结论本研究显示64层螺旋CT在左心功能定量评价方面准确、可靠,与3.0T磁共振两种方法各指标之间相关性高。一次MSCT冠状动脉成像检查,可以同时评估冠状动脉狭窄情况和左心室功能。 Objective To assess functional parameters of left ventricle with 64-slice CT (MSCT) and the results were compared with MRI. Methods End-diastolic-volume (EDV), end-systolic-volume (ESV), stroke-volume (SV), ejection-fraction (EF), and myocardial mass (MM) were calculated based on CT data sets from 20 patients scheduled for noninvasive MSCT angiography of the coronaries suspected coronary artery disease (CAD). The results from MSCT were compared with MRI. Results There was no significant difference among the measurements for MSCT and MRI of the ventricular function parameters. A strong correlation between MSCT and MRI (r=0. 72-0.92) was found for all parameters. However, EDV, ESV, SV, and MM were overestimated with MSCT compared to MRI, while EF was underestimated in MSCT. Conclusion A strong correlation between MSCT and MRI was found for all parameters. ECG-gated MSCT angiography of the heart is noninvasive assessment of the coronary tree, whereas the analysis of left ventricular parameters provides additional information of cardiac function without further radiation exposure or scan time.
出处 《中国医学影像技术》 CSCD 北大核心 2007年第1期66-69,共4页 Chinese Journal of Medical Imaging Technology
关键词 体层摄影术 X线计算机 磁共振成像 心室功能 Tomography, X-ray computed Magnetic resonance imaging Ventricular function, left
  • 相关文献

参考文献11

  • 1Emond M,Mock MB,Davis KB,et al.Long-term survival of medically treated patients in the coronary artery surgery study (CASS) registry[J].Circulation,1994,90(6):2645-2657.
  • 2Vourvouri EC,Poldermans D,Bax JJ,et al.Evaluation of left ventricular function and volumes in Patients with ischaemic cardiomyopathy:gated single-Photon emission computed tomography versus two-dimensional echocardiography[J].Eur J Nucl Med,2001,28(11):1610-1615.
  • 3Takuma S,Cabreriza SE,Sciacca R,et al.Determination of left ventricular mass by real-time three-dimensional echocardiography:in vitro validation[J].Echocardiography,2000,17(7):665-674.
  • 4Miller S,Simonetti OP,Carr J,et al.MR Imaging of the heart with cine true fast imaging with steady-state precession:influence of spatial and temporal resolution on left ventricular functional parameters[J].Radiology,2002,223(1):263-269.
  • 5Rathi VK,Biedermann RW.Imaging of ventricular function by cardiovascular magnetic resonance[J].Curr Cardiol Rep,2004,6(1):55-61.
  • 6赵希刚,李坤成,李永忠.单次屏气电影法MRI评价左心室功能的初步研究[J].中国医学影像技术,2005,21(1):65-67. 被引量:12
  • 7Klingerbeck-Regn K.Schaller S.Fhlor T.et al.Subsecond multislice computed tomography:basics and applications[J].Eur J Radiol,1999,31(2):110-124.
  • 8Chuang ML,Hibberd MG,Salton CJ,et al.Importance of imaging method over imaging modality in noninvasive determination of left ventricular volumes and ejection fraction:assessment by two-and three-dimensional echocardiography and magnetic resonance imaging[J].J Am Coll Cardiol,2000,35(2):477-484.
  • 9Mahnken AH,Spunt rup E,Wildberger JE,et al.Quantification of cardiac function with multiple spiral CT using retrospective ECG-gating:comparison with MRI[J].Rofo,2003,175 (1):83-88.
  • 10Boehm T,Alkadhi H,Roffi M,et al.Time-effectiveness,oberserver-dependence,and accuracy of measurements of left ventricular ejection fraction using 4-channel MDCT[J].Rofo,2004,176(4):529-537.

二级参考文献14

  • 1李坤成.心血管磁共振诊断学[M].北京:人民卫生出版社,1997.46-48.
  • 2Moon JC, Lorenz CH, Francis JM, et al. Breath-hold FLASH and FISP cardiovascular MR imaging:left ventricular volume difference and reproducibility[J]. Radology,2002,223(3):789-797.
  • 3Anand IS, Florea VG, Solomon SD, et al. Noninvasive assessment of left ventricular remodeling:concepts, techniques, and implication for clinical trials[J]. J Card Fail,2002,8(6 Suppl):452-464.
  • 4Chuang ML, Hibberd MG, Salton CJ, et al. Importance of imaging modality in noninvasive determination of left ventricular volumes and ejection fraction: assessment by two-and three-dimensional echocardiography and magnetic resonance imaging[J]. Am Coll Cardiol,2000,35(2):477-484.
  • 5Bogaert JG, Bosmans HT, Rademakers FE, et al. Left ventricular quantification with breath-hold MR imaging: comparison with echocardiography[J]. MAGMA,1995,3(1):5-12.
  • 6Mahnken AH, Spuntrup E, Wildberger JE, et al. Quantification of cardiac function with multiple spiral CT using retrospective ECG-gating: comparison with MRI[J]. Rofo Fortchr Geb Rontgenstr Neuen Bildgeb Verfahr, 2003,175(1):83-88.
  • 7Ye X, Noble JA, Atkinson D. 3-D echocardiography for automatic left ventricle reconstruction and analysis based on multiple acoustic windows[J]. IEEE Trans Med Imaging,2002,21(9):1051-1058.
  • 8Ioannidis JP, Trikalinos TA, Danias PG. Electrocardiogram-gated single-photon emission computed tomography versus cardiac magnetic resonance imaging for the assessment of left ventricular volumes and ejection fraction: a meta-analysis[J]. J Am Coll Cardiol,2002,39(12):2059-2068.
  • 9Sechtem U, Pflugfelder P, Higgins CB. Quantification of cardiac function by conventional cine magnetic resonance imaging[J]. Cardiovasc Intervent Radiol,1987,10(6):365-373.
  • 10Sakuma H, Takeda K, Higgins CB. Fast magnetic resonance imaging of the heart[J]. Eur J Radiol,1999,29(2):101-113.

共引文献11

同被引文献272

引证文献24

二级引证文献110

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部