摘要 目的对FS9901型生物防护口罩的防护效果进行测试评价。方法采用国家标准测试方法对该口罩的滤材过滤效率、通气阻力、负载能力、口罩脸形密合度进行测试。结果该口罩的过滤效率达到99%以上;通气阻力<250 Pa,低于正常使用标准;脸形密合度>200,超过了国际通用检测仪器的极限。结论该口罩是目前国内外防护用品市场上已有的防护性能最好的一次性生物防护口罩。此外,该口罩在使用时自动变为腔式结构,而在储存时为平面结构,体积小,重量轻,非常易于储运和使用。 Objective To evaluate the biological protection quality of FS9901 type respirator. Methods Using the testing method from respiratory protection standards of state. Results Aeration resistance, filter medium efficiency, and the actual wearing performance of face profile - mask fitness have been tested with standard methods. The results showed that the filtration efficiency of mask was above 99 percent with the aeration resistance less than 250 Pa which below the standards, and the face profilemask fitness of FS9901 exceed 200 which is detection capacity of the international standard test set. Couclusion The respirator of FS9901 offered the best biological protection quality of all the protection equipments in intemalional market. Besides, this new respirator has the cavity constmction style when used, while has flat suxface construction form with smaller physical volume and more lighter weight when stored.It is beneficial to be stored and transported.
出处 《中国预防医学杂志》 CAS 2007年第1期27-29,共3页 Chinese Preventive Medicine
关键词 测试 FS9901 口罩 防护性能 Testing FS9901 respirator Biological protection quality
  • 相关文献

参考文献9

  • 1Office of the Federal Register.Code of federal regulations.part 84- approval of respiratory protective devices.Washington DC: Office of the Federal Register, National Archives and Records Admirdstration. 1996,42 CFR part 84.
  • 2Surgical Masks-Prmarket Notification[510' (k)].Submissions Guidance for Industry and FDA, 2004.
  • 3国家质量监督检验免疫总局.医用防护口罩技术要求.GB19083—2003.
  • 4鹿建春,孟令英,李军保,陈刚,刘经南,车凤翔.中国人脸形分布与生物防护口罩设计研究[J].中国消毒学杂志,2004,21(4):313-315. 被引量:20
  • 5鹿建春,孙振海,李劲松,孟令英,王洁,赵建军.生物防护口罩的研制及其防护效果评价[J].中国消毒学杂志,2004,21(3):189-192. 被引量:25
  • 6OSHA.Respiratory Protection Standards 29 CFR 1910.134, 1998.
  • 7Andersen AA.New sampler for the collection, sizing, and enumeration of viable airbome particles.J Bacteriol, 1958, 76:471-484.
  • 8CDC. Laboratory performance evaluation of N95 filtering facepiece respirator, 1996.MMWR Morb Mortal Wkly Rep, 1998, 47: 1045-1049.
  • 9Coffey CC, Lawrence RB, Campbell DL.Fitting characteristics of eighteen N95 filtering - facepiece respirators.J Occup Environ Hyg, 2004,1: 262-271.

二级参考文献6

  • 1[1]Lowery, PR. Hesch and W H. Revior: Performance of single-use respirators [J]. Am. Ind. Hyg. Assoc. J. , 1977; 38: 462.
  • 2[2]William C. Hinds and Gerhard Kraske: performance of dust respirators with facial seal leaks: I[J]. Experimental. Am. Ind. Assoc. J. 1987; 48(10):836.
  • 3Department of Health and Human Services.NIOSH recommended guidelines for personal respiratory protection of workers in health-care facilities potentially exposed to tuberculosis [M].Atlanta,Georgia,1992.
  • 4U.S.Department of Interior Bureau of Mines.American national standard practices for respiratory protection [S].American National Standards Institute,Inc,New York,1969.
  • 5Dooley SW,Castro KG,Hutton MD,et al.Guidelines for Preventing the transmission of tuberculosis in health-care settings,with special focus on HIV-related issues [J].MMWR 1990;39:(RR-17).
  • 6Mary DH,Jacquelyn AP.Guidelines for preventing tuberculosis transmission in health care settings:What's new? Am J Infect Control,1992;20:24.

共引文献40

同被引文献36

引证文献4

二级引证文献33

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部