期刊文献+

合肥光源X射线成像光束线和实验站设计 被引量:4

The design of X-ray imaging beamline and endstation on Hefei light source
在线阅读 下载PDF
导出
摘要 在X射线成像光束线光学系统的设计基础上,对光束线的能量分辨率和光子通量进行了计算,并对双晶单色器第一块晶体的热载影响进行了模拟分析,同时利用波带片成像技术对实验站进行了设计,达到了60 nm的空间分辨率.结果表明光束线和实验站的设计能够满足X射线成像实验所需条件的要求. Based on the design of the optical system for X-ray imaging beamline, the calculation of the photon flux and energy resolution about the beamline was presented. Furthermore, the simulation of the thermal equilibrium process of the heating effect was introduced, which was performed on the first crystal of the double crystal monochromator. To meet the demand of the 60 nm spatial resolution, the zone plate imaging technology must be employed. The results indicate that the design of the beamline and station completely can meet the demand of the X-ray imaging experiments.
出处 《中国科学技术大学学报》 CAS CSCD 北大核心 2007年第1期93-98,共6页 JUSTC
基金 国家自然科学基金(10675113)资助
关键词 X射线成像 光子通量 能量分辨率 波带片 X-ray imaging photon flux energy resolution zone plate
  • 相关文献

参考文献12

  • 1Chao W, Harteneck B D, Liddle J A, et al. Soft X-ray microscopy at a spatial resolution better than 15 nm[J]. Nature, 2005, 435:1 210-1 213.
  • 2Yun W B, Chrzas J, Viccaro P J. Finite thickness effect of a zone plate on focusing hard X-rays[C]//Advanced X-ray/EUV Radiation Sources and Applications , Proc of SPIE. SPIE , 1991, 1 345:146-164.
  • 3Winik H, Doniach S. Synchrotron Radiation Research[M]. New York: Plenum Press, 1980:501.
  • 4MacDowell A A, Norman D, West J B. Soft X-ray beam line for surface EXAFS studies in the energy range 60≤hv≤11 100 eV at the Daresbury SRS[J].Rev Sci Instrum, 1986, 57(11):2 667-2 679.
  • 5凤良杰,董晓浩,高飞,康乐,赵飞云,徐朝银.NSRL-XAFS光束线弧矢聚焦双晶单色器设计[J].中国科学技术大学学报,2006,36(7):761-766. 被引量:3
  • 6董晓浩,凤良杰,徐朝银.NSRL-U7C双晶单色器热载影响与计算分析[J].核技术,2006,29(1):6-10. 被引量:4
  • 7Sparks C J, Borie B S. X-ray monochromator geometry for focusing synchrotron radiation above 10 keV [J].Nucl Instrum Methods, 1980, 172 : 237-242.
  • 8徐向东,洪义麟,付绍军,张允武.X射线波带片[J].物理,1998,27(5):293-297. 被引量:2
  • 9Leitenberger W, Weitkamp T, Drakopoulos M, et al.Microscopic imaging and holography with hard X-rays using Fresnel zone-plates[J]. Optics Communications,2000, 180:233-238.
  • 10Kaulich B, Oestreich S, Salome M, et al.Feasibility of transmission X-ray microscopy at 4 keV with spatial resolutions below 150 nm[J]. Applied Physics Letters,1999,75 : 4061-6063.

二级参考文献21

  • 1董晓浩,凤良杰,徐朝银.NSRL-U7C双晶单色器热载影响与计算分析[J].核技术,2006,29(1):6-10. 被引量:4
  • 2Winik H, Doniach S. Synchrotron Radiation Research[M]. New York:Plenum, 1980: 501.
  • 3MacDowell A A, et al. Soft X-ray beam line for surface EXAFS studies in the energy 60 ≤ hγ≤ 11 100 eV at the Daresbury SRS[J]. Rev. Sci. Instrum, 1986,57(11):2 667.
  • 4Caciuffo R, Ferrero C. Theoretical reflectivities of bent crystal analyzers for fusion plasma diagnostics[J]. Rev. Sci. Instrum,1990,61(11) :3 469-3 472.
  • 5Sparks C J, Borie B S. X-Ray Monochromator geometry for focusing synchrotron radiation above 10 keV[J]. Nacl. Instrum. Methods, 1980,172 : 237-142.
  • 6Ice G E. Sparks C J. Conical geometry for sagittal focusing as applied to X rays from synchrotrons[J]. Opt. Soc,1994,11(4):1 266-1 267.
  • 7Zhang L, Hustache R. Design optimization of a flexural hinge-based bender for X-ray optics[J]. Synchrotron Rad, 1998,5 : 804-807.
  • 8傅绍军,光学学报,1995年,15卷,1148页
  • 9XU Chaoyin, PAN Guoqiang, XU Faqiang, et al. Nucl Instr Meth, 2001, A467-468:639-642.
  • 10XU Chaoyin, ZHAO Weichang, PAN Guoqiang, et al.Nucl Inslr Meth, 1998, A410:293-296.

共引文献6