用复合水稳药剂对高炉炉体冷却水进行水质稳定处理,系统处理后结垢附着速度0.14.m·c·m,腐蚀速度0.033mm/a.本法应用于石家庄钢铁厂高炉净环水.
Combined water stabilization agent has been employed in the paper to treat the cooling water in the body of blast furnace and the scale deposition rate decreased to 0.14m·c·m and corrosion rate was lowered to 0. 033mm/a after treatment, which was applied in the blast furnace of Shijia-zhuang Iron & Steel Works one and half years ago.