期刊文献+

全自动血液分析仪在检测血小板细菌污染中的应用 被引量:4

暂未订购
导出
摘要 目的评价BacT/ALERT系统在检测血小板细菌污染中的应用。方法用BacT/ALERT系统对所制备的血小板悬液2164袋(含手工采去白细胞混合血小板及机器采集血小板)进行细菌污染检测,阳性标本作细菌鉴定。结果2164袋血小板悬液中细菌培养阳性25袋(1.16%),其中厌氧菌0.60%,需氧菌0.42%,厌氧菌与需氧菌均阳性0.14%。手工采混合血小板的阳性率为1.60%,厌氧菌占0.80%,需氧菌占0.58%,两者均阳性占0.22%。机采血小板的阳性率为0.38%,厌氧菌占0.25%,需氧菌占0.13%。细菌鉴定结果1袋为假阳性。结论BacT/Alert系统全自动血液分析仪具有快速、灵敏度较高以及假阳性率较低的优点。
出处 《中国输血杂志》 CAS CSCD 2006年第6期459-460,共2页 Chinese Journal of Blood Transfusion
  • 相关文献

参考文献9

  • 1Blajchman MA,Goldman M,Baeza F.Improving the bacteriological safety of platelet transfusions[J].Transfus Med Rev,2004,18(1):11
  • 2Soeterboek AM,Welle FH,Marcelis JH,et al.Sterility testing of blood products in 1994/1995 by three cooperating blood banks in the Netherlands[J].Vox Sang,1997,72(1):61
  • 3Liu HW,Yuen KY,Cheng TS,et al.Reduction of platelet transfusion-associated sepsis by short-term bacterial culture[J].Vox Sang,1999,77(1):1
  • 4Blajchman MA.Bacterial contamination of blood products[J].Transfus Apher Sci,2001,24(3):245
  • 5Castro E,Bueno JL,Barea,et al.Feasibility of implementing an automated culture system for bacteria screening in platelets in the blood bank routine[J].Transfus Med,2005,15(3):185
  • 6Mohammadi T,Pietersz RN,Vandenbroucke-Grauls CM,et al.Detection of bacteria in platelet concentrates:comparison of broad-range real-time 16S rDNA polymerase chain reaction and automated culturing[J].Transfusion,2005,45(5):731
  • 7Larsen CP,Ezligini F,Hermansen NO,et al.Six years' experience of using the BacT/ALERT system to screen all platelet concentrates,and additional testing of outdated platelet concentrates to estimate the frequency of false-negative results[J].Vox Sang,2005,88(2):93
  • 8Blajchman MA,Goldman M,Baeza F.Improving the bacteriological safety of platelet transfusions[J].Transfus Med Rev,2004,18(1):11.
  • 9McDonald CP,Hartley S,Orchard K,et al.Fatal Clostridium perfringens sepsis from a pooled platelet transfusion[J].Transfus Med,1998,8(1):19

同被引文献36

  • 1刘仁强,刘赴平,叶柱江,秦艳兰.3073例输注血小板细菌培养结果分析[J].中国热带医学,2006,6(5):868-868. 被引量:11
  • 2WS/T414-2013.室间质量评价结果应用指南.
  • 3Dodd RY,Notari EPT,Stramer SL.Current prevalence and incidence of infectious disease markers and estimated window-period risk in the American Red Cross blood donor population [J].Transfusion, 2002,42(8):975 -9759.
  • 4Busch MP, Kleinman SH, Nemo GJ. Current and emerging infec- tious risks of blood transfusions[J],JAMA,2003,289(8):959-962.
  • 5Strainer SL,Glynn SA,Kleinman SH,et al. Detection of HIV-1 and HCV infections among antibody-negative blood donors by nucleic acid-amplification testing[J]. N Engl J Med,2004,351(8):760-768.
  • 6Silva MA, Gregory KR, Ca.n'-GreerMA, et al. Summary of the AABB in terorganiz ational task force on bacterial contamination of platelets: fall 2004 impact survey [J].Transfusion,2006,46 (4):636- 641.
  • 7Fang CT, Chambers LA, Kennedy J, et al. Detection of bacterial contamination in apheresis platelet products: American Red Cross experience, 2004[J]. Transfusion, 2005,45(12):1845-1852.
  • 8Perez P,Salmi LR,Fo!lea G,et al. Determinants of transfusionasso- elated bacterial contamination: results of the French BAC THEM Case-Control Study[J]. Transfusion,2001,41(7):862-872.
  • 9国家药典委员会.中华人民共和国药典三部,2010:附录89-92.
  • 10Davenport P,Land KJ.Isolation of Leclercia adecarboxy lata from the blood culture of an asymptomatic platelet donor.Transfusion,2007,47(10):1816-1819.