期刊文献+

Fluoro Trigger技术在肝脏磁共振血管成像中的应用价值 被引量:7

Applied value of Fluoro Trigger technique in 3D contrast-enhanced MR angiography of hepatic vessels
暂未订购
导出
摘要 目的探讨Fluoro Trigger技术在肝脏磁共振血管成像中的应用价值。方法52例行肝脏磁共振血管成像患者及20例对照组患者,利用自动透视触发技术进行肝脏血管成像,对比剂到达降主动脉起始段时启动3D扫描,扫描时相包括肝动脉期、门静脉期及腔静脉期,分离各组图像并与蒙片剪影,再进行最大信号强度投影(MIP)法及多平面重建(MPR)图像重组,并评价各期图像质量。结果采用此方法,肝动脉期及门静脉期图像质量满意;对比剂到达降主动脉起始段时间与对比剂流速、总量之间呈线性相关;对比剂总量和流速与肝血管信号强度呈正相关。结论Fluoro Trigger技术可准确把握对比剂到达靶血管时间,结合最佳的对比剂总量和注射速度,能够明显提高肝脏磁共振血管成像质量。 Objective To investigate the applied value of Fluoro Trigger technique in 3D CE-MRA of hepatic vessels. Methods Fluoro Trigger was performed in 72 cases. When contrast material arrived in the descending aorta, 3D scan started. Artery phase, portal vein phase, vena cava phase were acquired. The images were subtracted and reconstructed by MIP or MPR. The quality of image was evaluated. Results With this technique, high quality images were obtained. Contrast volumes and flow rate correlated with the time when bolus reached the target vessel. Contrast volume and flow rate had linearity correlation with the signal of hepatic vessel. Conclusion Fluoro Trigger technique can control the exact time when contrast material reached target vessel. When combined with best contrast volume and flow rate, it can improve the image quality obviously.
出处 《中国医学影像技术》 CSCD 北大核心 2006年第11期1720-1724,共5页 Chinese Journal of Medical Imaging Technology
关键词 磁共振成像 血管造影术 Magnetic resonance imaging Angiography
  • 相关文献

参考文献11

  • 1张照喜,陈宪,徐宁,刘玉林,郑之青,蒋春林.iPass技术在腹部3D-CE-MRA中的应用[J].放射学实践,2005,20(1):77-80. 被引量:6
  • 2Riederer SJ,Fain SB,Kruger DG,et al.Real-time imaging and triggering of 3D contrast-enhanced MR aniograms using MR fluoroscopy[J].MAGMA,1999,8(3):196-206.
  • 3Fain SB,King BF,Breen JF,et al.High-spatial-resolution contrast-enhanced MR angiography of the renal arteries:a prospective comparison with digital subtraction angiography[J].Radiology,2001,218(2):481-490.
  • 4Butz B,Dorenbeck U,Borisch I,et al.High-resolution contrast-enhanced magnetic resonance angiography of the carotid arteries using fluoroscopic monitoring of contrast arrival:diagnostic accuracy and interobserver variability[J].Acta Radiol,2004,45(2):164-170.
  • 5陶玲,王惠南,田芝亮.三维对比增强磁共振血管造影中的透视触发技术研究[J].生物医学工程学杂志,2005,22(6):1134-1139. 被引量:3
  • 6方佳,贾宁,吴晓明,冯祥太,汤艳萍,宋发亮,郭佑民.动态增强MRA在胸腹部大血管成像中的应用[J].实用放射学杂志,2004,20(9):854-855. 被引量:7
  • 7Carr JC,Nemcek AA Jr,Abecassis M,et al.Preoperative evaluation of the entire hepatic vasculature in living liver donors with use of contrast-enhanced MR angiography and true fast imaging with steady-state precession[J].J Vasc Interv Radiol,2003,14(4):441-449.
  • 8Erden A,Erden I,Yagmurlu B,et al.Portal venous system:evaluation with contrast-enhanced 3D MR portography[J].Clin Imaging,2003,27(2):101-105.
  • 9Kopka L,Vosshenrich R,Rodenwaldt J,et al.Differences in injection rates on contrast-enhanced breath-hold three-dimensional MR angiography[J].AJR,1998,170:345-348.
  • 10Lee MG,Park KB,Shin YM,et al.Preoperative evaluation of hilar cholangiocarcinoma with contrast-enhanced three-dimensional fast imaging with steady-state precession magnetic resonance angiography:comparison with intraarterial digital subtraction angiography[J].World J Surg,2003,27(3):278-283.

二级参考文献22

  • 1Earls JP,Rofsky NM,Decorato DR,et al. Breath-hold Single-dose Gadolinium-enhanced Three-dimensional MR Aortography: Usefulness of a Timing Examination and MR Power Injector[J]. Radiology , 1996,201 (3): 705-710.
  • 2Foo TK,Saranathan M,Prince MR,et al. Automated Detection of Bolus Arrival and Initiation of Data Acquisition in Fast,Three-dimensional,Gadolinium-enhanced MR Angiography[J]. Radiology,1997,203(1) :275-280.
  • 3Prince MR,Narasimham DL,Stanley JC,et al. Breath-hold Gadolinium-enhanced MR Angiography of the Abdominal Aorta and its major Branches[J]. Radiology, 1995,197(3): 785-792.
  • 4Maki JH,Prince MR, Londy FJ,et al. The Effects of Time Varying Intravascular Signal Intensity and K-Space Acquisition Order on Three-Dimensional MR Angiography Image Quality [J]. J Magn Reson Imaging,1996,6(4):642-651.
  • 5Riederer SJ, Bernstein MA, Breen JF, et al. Three-dimensional Contrast-enhanced MR Angiography with Real-time Fluoroscopic Triggering:Design Specifications and Technical Reliability in 330Patient Studies[J]. Radiology,2000,215(2) :584-593.
  • 6Lee JJ,Tirman PJ,Chang Y, et al. The Optimization of Scan Timing for Contrast-Enhanced Magnetic Resonance Angiography[J].Korean J Radiol, 2000,1(3): 142-151.
  • 7Prince MR,Chenevert TL,Foo TK, et al. Contrast-enhanced Abdominal MR Angiography:Optimization of Imaging Delay Time by Automating the Detection of Contrast Material Arrival in the Aorta[J]. Radiology, 1997,203(1): 109-114,
  • 8Lentschig MG, Reimer P, Rausch-Lentschig UL, et al. BreathHold Gadolinium-Enhanced MR Angiography of the Major Vessels at 1.0T Dose-response Findings and Angiography[J]. Radiology, 1998,208(2): 353-357.
  • 9Hany TF, Debation JF, Leung DA, et al. Optimization of Contrast Timing for Breath-hold Three-dimensional MR Angiography[J]. Radiology,1997,204(5) :357-362.
  • 10Ho VB,Foo TK. Optimization of Gadolinium-Enhanced Magnetic Resonance Angiography Using an Automated Bolus-Detection Algorithm (MR SmartPrep) Original Investigation [J]. Invest Radiol,1998,33(9) :515-523.

共引文献11

同被引文献50

引证文献7

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部