摘要
针对河南神马尼龙化工公司化学水装置阳离子交换器出现的出力不足问题,从工艺、设备、树脂、再生系统等方面认真查找和分析,确认是树脂及盐酸存在问题,并采取措施加以解决,给其他化学水处理装置提供了参考和借鉴。
Aiming at the problem of the flux shortage happened at the cation exchange reactor of the chemical water equipment in Henan Shenma Nylon Chemical Co., Ltd., the techniques, equipment, resin, regenerating system, etc. have been analyzed. It is found out that the problem is caused by resin and HCl. Some effective measures have been taken to solve this problem. They provide other chemical water treatment equipment with reference.
出处
《工业水处理》
CAS
CSCD
北大核心
2006年第11期90-92,共3页
Industrial Water Treatment
关键词
阳离子交换器
碎树脂
有机物污染
碱处理
cation exchange reactor
broken resin
organic pollution
treatment with NaOH solution