摘要
认为减少风亭设置数量是解决地面风亭设置困难的有效途径,可最大限度地减少土建工程量和工程投资。结合广州地铁环控系统设计,提出风道、风亭合用设计的思路,并详尽分析两种设计方案的情况。
Author of the paper deems that reducing the num ber of air kiosks is an effective approach to avoid the difficulties of setting them on the ground surface and diminish the amount of civil engineering works and project investment to a great extent. In accordance with the design of the environmental control system of Guangzhou metro, an idea of the combined utilization of ventilation ducts and air kiosks is presented together with detailed analysis of two options.
出处
《都市快轨交通》
2006年第5期43-47,共5页
Urban Rapid Rail Transit
关键词
地铁
车站通风空调
隧道通风
合用设计
风亭
Guangzhou metro
ventilation and aircondition of station
combined design
air kiosks