期刊文献+

准分子激光原位角膜磨镶术非接触眼压测量值分析 被引量:1

Analysis of non-contact IOP following LASIK
暂未订购
导出
摘要 目的:探讨准分子激光原位角膜磨镶术(laserinsituker-atomileusis,LASIK)后眼压测量值的影响因素。方法:对1100例(2200眼)近视患者行LASIK并随访1a,记录手术前后的眼压值(非接触眼压测量)。结果:LAISK术后3,6,12mo的眼压值,均较术前有明显下降。结论:LASIK术后眼压测量值低于术前。角膜切削深度量的大小是影响术后眼压高低的重要因素。 AIM: To determine the influential factors of intraocular pressure (IOP) measured value following laser in situ keratom ileusis(LASIK). METHODS: 1 100 cases (2 200 eyes) patients with myopia were treated by LASIK, and followed up 1 year, IOPs were measured by non-contact tonometer before and after surgery respectively. RESULTS: IOP values of LASIK postoperation 3,6 and 12 months were all significantly decrease compared with the preoperative reading. CONCLUSION: IOP measured value of LASIK postoperation is lower than that of preoperation, the ablating depth of cornea is an important factor to influence on the measured value of postoperative IOP.
作者 张学玲
机构地区 解放军
出处 《国际眼科杂志》 CAS 2006年第5期1229-1230,共2页 International Eye Science
关键词 准分子激光原位角膜磨镶术 眼压 近视 laser in situ keratomileusis intraocular pressure myopia
  • 相关文献

参考文献2

二级参考文献8

  • 1[2]Faucher A, Gregoire J, Blondeau P, Accuracy o Glodmann tonometry after Refrctyve surgery[J]. Jcataract Refract surg 1997.832-838.
  • 2[3]Chatterjee A, Shah S, Bessant DA, et al. Reduction in intraocular pressure after excimer Laser photorefraetfive kerarectnmg. Correlation with pretreatmnet myopia[J]. Ophthalmology 1997.355 - 359.
  • 3Chatterjee A,Shah S,Bessant DA, et al. Reduction in intraocular pressure after excimer laser photorefactive keratectomy: correlation with pretreatment myopia[J ]. Ophthalmology, 1997,104: 355-359.
  • 4Tuunanen TH, Hamalainen P, Mall M, et al. Effect of photorefractive keratectomy on the accuracy of pneumatonometer readings in rabbits [J ]. Invest Ophthalmol Vis Sci, 1996,37:1810-1814.
  • 5Schipper I, Senn P, Niesen U, et al. Are we measuring the right intraocular pressure after excimer laser photorefractive laser keratoplasty in myopia? [J]. Klin Monatsbl Augenheilkd, 1995,206 : 322-324.
  • 6Copt RP, Thomas R, Mermound A. Corneal thickness in ocular hypertension, primary open angle glaucoma and normal tension glaucoma [ J ]. Arch Ophthalmol, 1999,117:1416.
  • 7Mark HH. Corneal curvature in applanation tonometry[J ]. Am J Ophthalmol, 1973,76 : 223-224.
  • 8潘怡,张泳,廉井财,王康孙.准分子激光原位角膜磨镶术后眼压和角膜厚度的研究[J].中华眼科杂志,1999,35(5):359-362. 被引量:31