期刊文献+

基于均匀设计和最小二乘支持向量机的电容层析成像传感器优化设计 被引量:12

The Optimizing Design of Capacitance Tomography Sensors Based on Uniform Design and LS-SVM
在线阅读 下载PDF
导出
摘要 提出一种采用均匀设计与最小二乘支持向量机相结合的电容层析成像传感器结构参数优化方法.该方法以敏感场均匀度为设计目标,采用均匀设计安排试验,试验因素包括ECT传感器的4个重要参数即:极板张角,绝缘管道材料相对介电常数,管道壁厚,以及屏蔽罩与电容极板间的间距.运用最小二乘支持向量机对试验结果进行回归分析,并用因素轮换法进行寻优计算,从而得出优化的传感器结构参数.结果表明:经过优化的电容成像系统具有较好的成像效果.该方法试验次数少,具有较强的实用性. Uniform design and Least Square Support Vector Machines (LS-SVM) were applied to optimize design parameters of capacitance tomography sensors in this paper. Experiments were performed with uniform design:the spatial sensitivity distribution was taken as the performance parameter, and four key parameters:the radian of electrodes, the permittivity of insulating pipe material, the thickness of pipe wall and the distance between earthed screen and electrodes were used as experimental factors. LS-SVM was used to establish the regression model based on the experimental results. Then, a set of optimum parameters was obtained from the regression model by the factor rotation method. Simulation results indicate that the presented method in this paper can find a set of optimal parameters for capacitance tomography sensors efficiently and effectively.
出处 《应用基础与工程科学学报》 EI CSCD 2006年第3期396-402,共7页 Journal of Basic Science and Engineering
基金 国家自然科学基金资助项目(No.50276062)
关键词 电容层析成像 优化设计 均匀设计 最小二乘支持向量机 capacitance tomography optimum design uniform design LS-SVM
  • 相关文献

参考文献11

二级参考文献39

  • 1王翠苹,李定凯,董国亚,吕子安.广义矢量模式匹配法在电容层析成像技术上的应用[J].中国电机工程学报,2004,24(8):219-223. 被引量:14
  • 2Xie C G, Stott A L, Plaskowski A et al. Design of capacitance electrodes for concentration measurement of two-phase flow [ J ]. Measurement Science and Technology, 1990, 1( 1 ) :65-78.
  • 3Xie C G, Huang S M, Hoyle B S et al. Electrical capacitance tomography for flow imaging: system model for development of image reconstruction algorithms and design of primary sensors[J]. IEEE Proc G, 1992, 139(1):89-98.
  • 4Xie C G. Mass flow measurement of solid in a gravity drop conveyor using capacitance transducer[ D]. U K : University of Manchester, 1988.
  • 5Xie C G, Huang S M, Hoyle B S. Elecrical capacitance tomography for flow imaging: system mode for development of image reconstruction algorithms and design of primary sensors[J]. IEE PROCEEDING-G. 1992, (139): 89-98.
  • 6Xie C G. 8-electrode capacitance system for two-component flow identification. Part1: Tomgraphic flow imaging[J]. IEE Proceedings-G, 1993, 140(3): 216-222.
  • 7Xie C G, Huang S M. Electrical capacitance tomography for flow imaging: system model for development of image reconstruction algorithms and design of primary sensor[J]. IEE Proc G, 1992, 139(1): 89-98.
  • 8Xie C G, Stott A L, Plaskowski A, et al. Design of Capactitance Electrodes for Concentration Measurement of Tow-Phase Flow[J]. Meas Sci Technol, 1990, (1): 65-78.
  • 9Yan Hua,Electronics Lett,1998年,34卷,20期,1936页
  • 10Xie C G,IEE Proc Circuit Device Sys,1994年,141卷,5期,357页