摘要
分析了将氨液分离器设计安装于低温冷库内的氨制冷系统的缺点,提出将氨液分离器及相关阀门搬迁至库外,改变热氨冲霜回液管设计的解决方法;并提供了氨液分离器安装高度的一种计算方法。
This article analyzes the shortcomings of an Ammonia Refrigeration System, which proposes installing ammonia liquid separator in the low temperature cold store. Moving ammonia liquid separator and its relied valves outside cold store and changing the design method of the liquid pipe of hot ammonia gas defrosting are presented as the solution; And also provides a method to calculate the installation height of ammonia liquid separator. Analysis,
出处
《制冷》
2006年第3期75-77,共3页
Refrigeration
关键词
分析
改造
氨制冷系统
氨液分离器
安装高度
Reforming, Ammonia refrigeration system, Ammonia liquid separator, Installation height