摘要
介绍了拥有热功率为29、58 MW燃煤热水锅炉各4台的天津市空港物流加工区的热源厂锅炉房的平面布置,确定了锅炉房的耐火等级及泄压措施。对锅炉房建筑结构、辅助用房、安全出口、楼梯间、地面、楼面、外窗、立面、采光及通风进行了探讨。
The plane layout of boiler room of heat source plant in Tianjin Airport Industrial Park, which has four coal-fired hot water boilers with thermal power of 29 MW and four coal-fired hot water boilers with thermal power of 58 MW, is introduced. The fire-resisting rating and pressure relief measures of the boiler room are determined. The architectural structure, auxiliary room, safety exits, stairwell, ground, floor, outside windows, facade, lighting and ventilation of boiler room are discussed.
出处
《煤气与热力》
2006年第10期39-41,共3页
Gas & Heat
关键词
燃煤供热锅炉房
建筑设计
耐火等级
泄压
coal-fired heat-supply boiler room
pressure relief architectural design
fire-resisting rating