期刊文献+

强化混凝—高效沉淀工艺控制城市溢流污水研究 被引量:8

Enhanced coagulation and high-rate sedimentation process for control of municipal combined sewer overflows
在线阅读 下载PDF
导出
摘要 介绍了一套合流溢流污水处理装置的工艺流程、单元设计及其主要特点;对SS、CODCr、TP和浊度分别为170~700mg/L、130~650 mg/L、1.2~6 mg/L和150~330 NTU的合流溢流污水的中试研究表明,该装置对合流溢流污水具有良好的处理效果,SS、CODCr、TP和浊度平均去除率分别超过84%、68%、78%和79%. A set of devices was developed for control of the municipal combined sewer overflows , and in this paper the process flow, operation unit design and the overall feature of this facility is presented. The inflow wastewater has parameters of 170~700mg/L, 130~650mg/L, 1.2~ 6 mg/L and 150~330 NTU for SS, COD_ Cr , TP and turbidity respectively. The experimental results indicated that this device has good treatment effects, the average removals of the SS, COD_ Cr , TP and turbidity reached 84%, 68%, 78% and 79% respectively.
出处 《给水排水》 CSCD 北大核心 2006年第9期23-25,共3页 Water & Wastewater Engineering
基金 上海市科委科技攻关项目"中心城区和新城市化地区面源污染控制关键与工程示范"子课题。
关键词 合流污水溢流(CSOs) 处理装置 强化絮凝 高效沉淀 Combined sewer overflows(CSOs) Treatment device Enhanced coagulation High-rate sedimentation
  • 相关文献

参考文献6

二级参考文献18

  • 1Jun Ho Lee,et al.Characterization of Urban Stormwater Runoff[J].Wat Res,2000,34(6):1773-1780.
  • 2USEPA 1999,832-F-99-042.Combined Sewer Overflow Technology Fact Sheet Retention Basins[S].
  • 3R M Alkhaddar,et al.Residence Time Distribution of a Model Hydrodynamic Vortex Separator[J].Urban Water,2001,3:17-24.
  • 4Zdenik K,et al.Practical Applications of Vortex Flow Separators in the Czech Republic[J].Wat.Sci.Tech.,1996,33(9):253-260.
  • 5M C Boner,et al.Modified Vortex Separator and UV Disinfection for Combined Sewer Overflow Treatment[J].Wat.Sci.Tech.,1995,31(3-4):263-274.
  • 6W De Cock,et al.The Feasibility of Flocculation in a Storage Sedimentation Basin[J].Wat.Sci.Tech.,1999,39(2):75-83.
  • 7USEPA 1999,832-F-99-034.Combined Sewer Overflow Technology Fact Sheet Chlorine Disinfection[S].
  • 8USEPA 1999,832-F-99-033.Combined Sewer Overflow Technology Fact Sheet Alternative Disinfection Methods[S].
  • 9F Diaz-Fierros T,et al.Contaiminant loads of CSOs at the wastewater treatment plant of a city in NW Spain[J].Urban Water,2002,4:291-299.
  • 10Ken J Hall,et al.Characterization and Aquatic Impacts lf combined Sewer Overflows in Greater Vancouver British Columbia[J].Wat.Sci.Tech.,1998,38(10):9-14.