摘要
利用固定生物膜滤池控制硫化氢气体是一种经济有效的方法。试验条件是:温度20℃~33℃、滤层喷淋水量600l/m3·d。当进气H2S浓度Cin≤230mg/m3,生物滤池H2S负荷L≤560gH2S/m3·d时,H2S去除率达到100%,当Cin≤570mg/m3,L≤2430gH2S/m3·d时,H2S去除率高于98%,出气中H2S浓度≤10mg/m3。
The control of hydrogen sulfide using biological fixed-film filter is an economical and effective method. The experimental conditions were temperature of 20~30℃ and water spray quantity of 600l/m ̄3(packing)·d. 100% of H2S removal efficiency was obtained at the loading rate≤560gH2S/m3·d with Cin≤230mg/m3 (infuent H2S concentration). However, up to 98% of H2S removal efficiency was obtained at the loading rate≤2430gH2S/m3·d with Cin≤570mg/m3 and Cout≤10mg/m3.
出处
《城市环境与城市生态》
CAS
CSSCI
CSCD
1996年第1期15-19,共5页
Urban Environment & Urban Ecology
基金
天津市自然科学基金