摘要
结合深圳市宝安区福永凤凰水厂的设计,阐述了翻板滤池过滤系统、配水配气系统、反冲洗系统的设计要点及注意事项,同时也针对翻板滤池的不足提出了建议。
Combined with the design of the Fuyong Phoenix Waterworks in Bao' an District of Shenzhen City, the paper introduces the critical issues in design of the filter shutter-type system, water and air distribution system and back-wash system, and points out the attention to be paid in the design. Suggestions are given to overcome the shortcoming of the shutter-type filter.
出处
《中国给水排水》
CAS
CSCD
北大核心
2006年第18期48-51,共4页
China Water & Wastewater
关键词
翻板滤池
反冲洗
自动控制
shutter-type filter
backwash
automatic control