摘要
结合高压加热器运行中存在的问题,分析了8号高压加热器疏水端差大的原因,并提出了减小端差的方法。
With the extant problems in HP heaters , this paper analyzes the reason of condensate water discharge overheating in No. 8 HP heaters, and puts forward the method to reduce terminal temperature difference.
出处
《华北电力技术》
CAS
2006年第9期52-54,共3页
North China Electric Power
关键词
高压加热器
端差
疏水
过热
HP heaters
terminal temperature difference
water discharge
overheating