期刊文献+

非小细胞肺癌的三维适形放疗的临床实施 被引量:9

原文传递
导出
摘要 随着计算机技术和医学影像技术进步,肿瘤放疗技术从二维常规放疗进入了三维适形放疗(3DCRT)时代。3DCRT是一种治疗技术,使得高剂量区剂量分布形状在三维方向上与病变(靶区)形状一致。相对于传统放疗其准确性明显提高,可使肿瘤组织得到更高剂量,同时能够更好地保护周围正常组织,提高了治疗比。在临床应用越来越广泛,特别是非小细胞肺癌中替代常规放疗已成为趋势。3DCRT是一种高精度放疗,其实施过程需要有严格的流程和规范。笔者现将3DCRT在肺癌放疗实施流程及每一步骤基本要求进行讨论。
出处 《中华放射肿瘤学杂志》 CSCD 北大核心 2006年第5期392-395,共4页 Chinese Journal of Radiation Oncology
  • 相关文献

参考文献30

  • 1Cascade PN,Gross BH,Cazerooni EA,et al.Variability in the detection of enlarged mediastinal lymph nodes in staging lung cancer:a comparison of contrast-enhanced and unenhanced CT.Am J Radiol,1998,170:927-931.
  • 2van Sornsen de Koste JR,de Boer HCJ,Schuchhard-Schipper RH,et al.Procedures for high precision setup verification and correction of lung cancer patients using CT simulation and digitally reconstructed radiographs.Int J Radiat Oncol Biol Phys,2003,55:804-810.
  • 3McGibney C.Impact of intravenous contrast on target definition in radiotherapy of non small cell lung cancer.Eur J Cancer,2001,37 Suppl 6:211.
  • 4Giraud P.Influence of CT images visualization parameters for target volume delineation in lung cancer.Radiother Oncol,2001,57 Suppl 1:S39.
  • 5Mountain CF,Dresler CM.Regional lymph node classification for lung cancer staging.Chest,1997,111:1718-1723.
  • 6Caldwell CB,Mah K,Ung YC.Observer variation in contouring gross tumor volume in patients with poorly defined non-small-cell lung tumors on CT:the impact of 18FDG-hybrid PET fusion.Int J Radiat Oncol Biol Phys,2001,51:923-931.
  • 7Nestle U,Walter K,Schmidt S.18F-Deoxyglucose Positron EmissionTomography (FDG-Pet) for the planning of radiotherapy in lung cancer:high impact in patients with atelectasis.Int J Radiat Oncol Biol Phys,1999,44:593-597.
  • 8Giraud P,Antoine M,Larrouy A,et al.Evaluation of microscopic tumor extension in non-small cell lung cancer for three-dimensional conformal radiotherapy planning.Int J Radiat Oncol Biol Phys,2000,48:1015-1024.
  • 9Kara M,Sak SD,Orhan D,et al.Changing patterns of lung cancer; (3/4 in.) 1.9 cm; still a safe length for bronchial resection margin?.Lung Cancer,2000,30:161-168.
  • 10Rosenzweig KE,Sim SE,Mychalczak B,et al.Elective nodal irradiation in the treatment of non-small-cell lung cancer with three-dimensional conformal radiation therapy.Int J Radiat Oncol Biol Phys,2001,50:681-685.

同被引文献68

引证文献9