期刊文献+

±500 kV直流输电系统电磁环境调查研究 被引量:18

Research on the EM Environment of HVDC Transmission System
在线阅读 下载PDF
导出
摘要 为考虑我国直流特高压输电工程的电磁环境保护问题,调查了国内已有4条±500 kV高压直流输电线路电磁环境。根据问卷调查及实地测量给出了相应的调查结果以及由实测数据统计得出一些典型情况的合成场、离子流场大小及分布规律;通过与国际相关的限值标准比较,得出我国目前直流输电线路合成电场及离子流场对人体安全的结论,可供±800 kV特高压直流输电参考。 To get the EM environment of the HVDC transmissions lines and give some reference for the coming ± 800 kV HVDC transmission system, four of the whole five 52500 kV operating HVDC systems are investigated. The years have been run, the transfer power and the type of the line are different. So plenty of data is gotten during the investigations. The effects of the HVDC on the human nearby are listed in the paper. It can show most of the mankind's attitude to the HVDC project. The electric strength and the ionized field above ground are measured. The measurement data of the electric strength and the ionized field of some classic cases are discussed in the paper. By comparing with the limitation of the corresponding criteria, the whole EM environment situation of the HVDC is provided . It has been found that the electric strength is less than the limitation provided by the ICNIRP and the ionized field strength is far below the safe guard. At the end of the paper, it gives some problems about the line that must be done such as the audible noise and the adsorption affect of the ionized field to the dust.
出处 《高电压技术》 EI CAS CSCD 北大核心 2006年第9期146-148,152,共4页 High Voltage Engineering
关键词 高压直流 电磁环境 合成场 离子流场 输电线路 HVDC EM environment electric field ionized field transsmission line
  • 相关文献

参考文献15

  • 1邬雄.输变电工程电磁环境影响及对策[R].武汉:武汉高压研究所,2004.
  • 2美国邦维尔电力管理局生态研究工作组.输电线路的电效应和生态效应评述[R].北京:水利电力部电力科学研究院译,1987,4.
  • 3CISPR Publication 18-1,Radio Interference Characteristics of Overhead Power Lines and High-voltage Equipment, Part 1 : Description of Phenomens[S], 1982.
  • 4CISPR Publication 18-2, Radio Interference Characteristics of Overhead Power Lines and High-voltage Equipment, Part 2: Methods of measurement and procedure for determining limits, Amendment 1[S],1993.
  • 5ICNIRP Guidelines. Guidelines for Limiting Exposure to Time-varying Electric, Magnetic, and Electromagnetic Fields(up to 300 GHz)[S]. International Commission on Non-Ionlzing Radiation Protection. 1998.
  • 6P. Sarrna, Maruvada. Corona Performance of A Conductor Bundle for Bipolar HVDC Transmission at ±750 kV[J]. IEEE Trans on Power Apparatus and Systems, 1977, 96(6); 1872-1881.
  • 7Chattier V I., Steams R D. Formulas for Predicting Audible Noise from Overhead High Voltage AC and DC I.ines[J]. IEEE Trans on Power Apparatus and Systems, 1981, 100(1) : 406-409.
  • 8A report prepared by a Task Force of the Corona and Field Effects Sub committee. A Comparison of Methods for Calculating Audible Noise of High Voltage Transmission Linesl[J]. IEEE Trans on Power Apparatus and Systems, 1982, 101(10): 864-868.
  • 9Yukio Nakano, Mitsuo Fukushima. Statistical Audible Noise Performance of Shiobara HVDC Test Line[J]. IEEE Trans on Power Delivery, 1990, 5(1): 290-296.
  • 10GB15707—1995,高压交流架空送电线无线电干扰限值[S],1995.

共引文献3

同被引文献323

引证文献18

二级引证文献251