摘要 为了研究±800 kV干式平波电抗器户内、外布置的可行性,基于该电抗器电感值的线性度较好不易饱和、运行维护简单等优点和现有运行经验,根据±800kV直流输电工程的初步方案和对相关制造厂调研,对换流站直流场中干式平波电抗器的户内、外布置方式技术、经济性比较。研究表明干式平波电抗器的户内、外布置方案均具有可行性。 Smoothing reactor is one of key equipments in ± 500kV HVDC projects. Compared with oil-immersed smoothing reactors, dry type ones have lots of advantages, such as, maintenance free, low-noise, and easy to be designed, produced and transported at home. So, dry type smoothing reactor is a rather better choice for HVDC. However, it is relatively less applied in today's domestic HVDC projects. According to the transportation and manufacture capacity, the dry type smoothing reactor may be adopted in future 800kV UHVDC project. It is very important that the arrangement scheme of dry-type smoothing reactor in 800kV UHVDC project. Studying the principal parameters and system's requirements of the 800kV UHVDC project, some main data can be gotten. Also, based on the characteristics and operation experience of dry-type smoothing reactor, the relative technical economy comparison of advantages and disadvantages for the reactor' s indoor or outdoor arrangement schemes had been put forward. Working with several main domestic manufactures, parameters for dry type smoothing reactor, such as, size, weight, cost of auxiliary equipments, etc. , had been collected by their concept design and experience. These data shows that, there will be less equipment investment and more operating cost when indoor arrangement scheme is adopted. In all, comparing outdoor arrangement with indoor arrangement, hoth schemes are feasihle for ± 800kV UHVDC project. As for one specified project, there shall be different commendatory schemes for different manufactures. The arrangement scheme shall he made after taking into account the factors, such as, floor area, construction investment, operating cost, etc.
作者 张燕秉 郑劲
出处 《高电压技术》 EI CAS CSCD 北大核心 2006年第9期114-116,162,共4页 High Voltage Engineering
关键词 高压直流 干式平波电抗器 换流站 户内、外布置 技术 经济性比较 HVDC dry- type smoothing reactor converter station indoor or outdoor arrangement technical economy comparision
  • 相关文献

参考文献14

二级参考文献14

  • 1梁艳萍,费增尧.变压器线圈涡流损耗的解析算法[J].哈尔滨电工学院学报,1993,16(4):293-298. 被引量:1
  • 2清华大学.电力系统过电压及其防护[M].北京:清华大学出版社,1982..
  • 3西洛琴斯基 王文端 蒋得福译.高压工程[M].北京:中国工业出版社,1964..
  • 4温祥龙 程杰英 王永勇.66 kV30 Mvar空心并联电抗器投切时的高频过电压[A]..中国城市供电学术年会论文集[C].,2002..
  • 5P E Burke, T C H Lau, T H Fawzi. Shilding of Air Core Reactors[J]. IEEE Trans. on Magnetics, 1983, 19(5): 2070-2071.
  • 6ANSI/IEEE C57.21—1981 500kvar以上并联电抗器的要求、术语和试验规范[S].
  • 7ANSI/IEEE C57.16-1953(R1971) 限流电抗器的技术要求、术语及试验标准[S].
  • 8IEC289—1988 电抗器标准[S].
  • 9GB10229—88 电抗器[S]. 1988.  
  • 10IEC351—89 Line traps for A.C power systems[S].

共引文献126

同被引文献61

引证文献8

二级引证文献54

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部