摘要
介绍一种简便、实用的血清糖化低密度及极低密度脂蛋白测定法。测定结果批内变异系数为2.9%,批间变异系数为3.8%,160名健康成人其中96名男性参考正常值为20.1±10.4;64名女性参考正常值为20.4±7.4,男女之间无统计学差异。本文还研究了不同干扰物试验,其中肌酐。尿素氮、葡萄糖、维生素C结果发现均无干扰,但血红蛋白浓度在80g/d1时有明显干扰。
A simple,convenient and practical methed for the detertion of serum glycosylated low density lipoprotein and glycosylated very low density lipoprotein was introduced. The CV value of intra-assay and interassay were 2.9%and 3.8%, respectively in 160 healthy adults were detected,including 96 men and 64 women.The reference values of men and women were 20. 1±10. 4 and 20.4±7.4, respectively.There were not statistically significant differences between men and women.In addition,several interference tests were performed.It was found that creatinine,blood urea nitrogen,glucose and vitamin C didn't interfere to this assay, but there was evident interference when concentration of hemoglubin was 80gl/d1.
出处
《天津医科大学学报》
1996年第3期66-68,共3页
Journal of Tianjin Medical University
关键词
血清糖化
低密度脂蛋白
诊断
极低密度脂蛋白
Serum glycosylaled low density lipoprotein
Polyethyleneglycol 6000(PEG 6000)
Diabetes Mellitus