期刊文献+

低温对生物脱氮除磷系统影响的试验研究 被引量:36

EFFECT OF LOW TEMPERATURE ON BIOLOGICAL NITROGEN AND PHOSPHORUS REMOVAL SYSTEM
在线阅读 下载PDF
导出
摘要 本试验主要研究了在低温条件下,生物脱氮除磷倒置A2/O工艺小试系统处理效果随温度的变化情况,并通过试验确定了所研究水质硝化效果变差的临界温度。试验结果表明:当进水温度下降到15~7℃时,小试的硝化及除磷效果会随之明显下降。该水质条件下生物硝化效果变差的临界水温为13℃。 The effect of temperature on biological nitrogen and phosphorus removal by reversed A^2/O process system was studied under the condition of low temperature to seek for the critical temperature to make the nitrification effect in the water studied get poor. It was shown that, when the influent temperature dropped to 15-7℃, the performance of nitrification and phosphorus removal lowered obviously. The lab test showed that the critical temperature to make the biological nitrification effect get poor was 13℃.
出处 《水处理技术》 CAS CSCD 北大核心 2006年第8期18-21,共4页 Technology of Water Treatment
基金 国家高技术研究发展计划(863)资助项目(2002AA328010) 山东省环保局项目(59738150)
关键词 低温 硝化 除磷 倒置A^2/O工艺 low temperature nitrification phosphorus removal reversed A2/O process
  • 相关文献

参考文献3

  • 1张锡辉,刘勇弟,译.废水生物处理[M].第二版.北京:化学工业出版社,2003:73-74.
  • 2Euiso Choi Daewhan, Rhu Zuwhan, Yun Euisin Lee. Temperature effects on biological nutrient removal system with weak municipal wastewater. Wat Sci Tech., 1998, 37(9):219-226.
  • 3Christine Helmer and Sabine Kunst. Low temperature effects on phosphorus release and uptake by microorganisms in EBPR plants[J]. Wat Sci Tech., 1998, 37(4-5):531-539.