摘要
目的:检测两种氧氟沙星片剂的生物利用度是否有差异。方法:9名志愿者交叉服用两种氧氟沙星片剂,用反相HPLC测定其血药浓度。结果:测得主要药物动力学参数为:试验片剂T1/2=6.08±0.81h,Tm=1.04±0.47h,cm=3.02±0.69μg/ml,AUC=19.61±0.99(μgh)/ml;对照片剂T1/2=5.44±0.92h,Tm=0.91±0.47h,cm=2.95±0.75μg/ml,AUC=19.20±1.51(μgh)/ml。
OBJECTIVE:To determine the difference of bioavailability between two ofloxacin tablets.METHOD:Two ofloxacin tablets from different factories were administrated crossing over in 9 volunteers.A reversed phase high performance liquid chromatography was used to determine ofloxacin in human plasma.RESULTS:The main pharmacokinetic of parmeters of sample tablets were T 1/2 =6.08±0.81 h,AUC=19.61±0.99 (μg·h)/ml,T m=1.04±0.47 h,c m=3.02±0.69 μg/ml,and those of the spiked sample tablets were T 1/2 = 5.44 ±0.92 h,AUC=19.20±1.51 (μg·h)/ml,T m=0.91±0.47 h,c m=2.95±0.75 μg/ml.CONCLUSION:There is no significant difference of bioavailability between two ofloxacin tablets(P>0.05).
出处
《中国药学杂志》
CAS
CSCD
北大核心
1996年第7期412-414,共3页
Chinese Pharmaceutical Journal
关键词
氧氟沙星
生物利用度
高效液相色谱
ofloxacin,high performance liquid chromatography,bioavailability