电极参数对电凝并式空气净化装置净化颗粒物的影响

Effect of Electrode Parameters on Particles Elimination by Using Electric Coagulation Indoor Air Cleaning System
在线阅读 下载PDF
导出
摘要 研究了一种新型高压高频(HV-HF)电凝并式空气净化系统,进行了电极参数的变化对该电凝并装置净化颗粒物效果的实验研究。实验结果表明:电凝并装置存在最佳的交直流电压之间的匹配。最佳匹配值为直流电压12kV,交流电压440V。粒径小于1μm的颗粒物,其净化效果受电极参数的影响较明显,粒径大于1μm的颗粒物,在不同的电极参数下净化效果差别不大。 A new type electric coagulation indoor air cleaning system, which had an excellent effect on particles elimination in indoor air, was introduced in this paper. The effect of electrode parameters on particles elimination by using electric coagulation indoor air cleaning system was studied in detail. The results showed that there was an optimum status between alternating current (440 V) and direct current (12 kV) in our experiments. The electrode parameters had a remarkable influence on small particles whose diameter was less than 1 μm, whereas the effect was indistinctive when the particle's diameter was in excess of 1 μm.
出处 《科技导报》 CAS CSCD 2006年第7期35-38,共4页 Science & Technology Review
关键词 室内空气净化 电凝并 颗粒物 电极参数 indoor air purifying electric coagulation particle electrode parameter