期刊文献+

基于采样点选择和矢量旋转的多载波CDMA定时跟踪方案

A Reduced Complexity Timing Tracking Scheme for Multi-Carrier CDMA Signals Based on Samples Selecting and Vector Rotation
在线阅读 下载PDF
导出
摘要 针对多载波CDMA系统的特点,该文提出一种基于采样点选择和矢量旋转的全数字定时跟踪方案。该方案充分利用准时路复相关矢量信息,通过矢量旋转得到非相干定时误差检测量,进行定时跟踪调整。理论分析和数值结果表明,该方案较传统的延迟锁定跟踪方案明显降低了实现复杂度,而且性能有所提高。 A reduced-complexity all-digital timing tracking scheme suited for multi-carrier CDMA signals is proposed and studied. Based on samples selecting and vector rotation of correlation output vector at only on time channel, timing error detection statistics are approximately acquired and timing adjustment are carried out. Theoretical and numerical results show that the new scheme has an improved performance and remarkable complexity simplicity as compared with the classical digital delay-locked loop.
出处 《电子与信息学报》 EI CSCD 北大核心 2006年第7期1238-1241,共4页 Journal of Electronics & Information Technology
关键词 多载波CDMA 延迟锁相环 矢量旋转 采样点选择 MC-CDMA, Delay-locked loop, Vector rotation, Samples selecting
  • 相关文献

参考文献7

  • 1Hara S, Prasad R. Overview of multicarrier CDMA. IEEE Communication Magazine, 1997, 35(12): 126-133.
  • 2Kondo S, Milstein L B. Performance of multicarrier DS CDMA systems. IEEE Trans. on Communications, 1996, 44(2): 238-246.
  • 3Schmidl T M, Cox D C. Robust frequency and timing synchronization for OFDM. IEEE Trans. on Communications,1997, 45(12): 1613-1621.
  • 4Minn H, Zeng M, et al.. On timing offset estimation for OFDM systems. IEEE Communications Letters, 2000, 4(7): 242-244.
  • 5曹叶文,项海格.多载波频率分集扩展频谱通信的同步原理分析[J].通信学报,1997,18(1):34-39. 被引量:6
  • 6汪晓阳,张朝阳,罗义军,崔燕燕,姚庆栋.利用采样点选择法实现DS-CDMA中频接收机的码片同步[J].电路与系统学报,2000,5(1):95-99. 被引量:6
  • 7Gaudenzi R D, Luise M. A digital chip timing recovery loop for band-limited direct sequence spread spectrum signals, IEEE Transon Communications, 1993, 41(11): 1760-1769.