摘要 由于原型血泵尚未成熟,为了节省高昂的制造成本和实验费用,实验用模型血泵的设计具有十分重要的意义。以所设计的某型轴流血泵为例,采用相似理论,详细阐述了其实验血泵的设计过程,得出了具体的设计参数。 Because the prototype blood pump still immaturity, for saving the high cost of manufacture and experiment, it has the very important meaning with the design of the experimental blood pump. In this text, we take the design of axial blood pump as an example, use the comparability principle, detailed elaborate the design process of the experimental blood pump, get the concrete design parameter.
出处 《机械工程与自动化》 2006年第4期65-67,共3页 Mechanical Engineering & Automation
基金 国家自然科学基金资助项目(50275151)
关键词 实验血泵 相似理论 设计 experimental blood pump the comparability principle design