期刊文献+

某混合式低压加热器水室壳体振动原因分析和处理措施 被引量:1

Reason analysis of water chamber shell vibration for a mixed-type low pressure heater and its handling method
在线阅读 下载PDF
导出
摘要 阐述了俄制ΠHCB-2000-Ⅱ型混合式加热器结构和工作原理,对低压加热器的凝结水入口管周围壳体振动原因进行了分析,提出了处理措施。改进后,低加壳体振动现象消失。 The structure and mechanism of HHCB - 2000 - Ⅱ mixed - type heater made in former Soviet Union was introduced and ,he reasons of shell vibration surrounding the condensed water entry pipe of low pressure heater were analyzed, and some countermeasures were presented to deal with them.
出处 《黑龙江电力》 CAS 2006年第3期208-211,共4页 Heilongjiang Electric Power
关键词 低压加热器 振动 两相流 流体脉动 low pressure heater vibration double phase flow liquid pulse
  • 相关文献

参考文献2

二级参考文献5

  • 1尚智.小波分析和人工神经网络数值方法在气液两相流动热工计算中的应用研究[M].西安:西安交通大学,2000..
  • 2裴智勇.加筋板流固耦合振动分析及试验研究:硕士学位论文[D].武汉理工大学,2001.
  • 3Xiaodong Wang. Analytical and computational approaches for some fluid-structure interaction analyses[J]. Computers & Structures, 1999(72): 423-433.
  • 4吴卫国,李祥宁.高速双体骨行艇总振动计算分析[J].工程力学,2000,3(A03):221-225. 被引量:1
  • 5万水,朱德懋.圆柱贮液器固液耦合模态分析[J].工程力学,2000,17(3):87-92. 被引量:7