摘要 目的:探讨建立CT扫描及三维重建技术观察人工耳蜗植入(CI)电极的方法,并比较不同CT扫描三维重建方法的耳蜗内植入电极的影像学特征及其临床应用价值。方法:6例CI患者全部作术后CT扫描并分别应用多层面重建的容积再现(VR)、平均密度投影(AIP)、表面遮盖显示技术(SSD)3种方法进行三维重建,观察人工耳蜗植入术后耳蜗内电极。结果:3种方法的三维重建图均可直观地显示电极形态、走行及其在耳蜗内植入的深度和植入电极与内耳的空间关系,并可清晰识别耳蜗内的电极数目。结论:CT扫描三维重建方法可直接观察植入电极的形态及位置,可准确判断电极在耳蜗内电极数目,有其独特的临床应用价值。 Objective:To discuss the different methods of computed tomography (CT) scans and three dimensional reconstruction of inner ear with implanted electrodes, and to evaluate the value and image features of these methods. Method:Six cochlear implant (MEDEL Combi 40 +,Advanced Bionics ) recipients were involved in this study. The implanted electrodes of all patients were examined on the seventh postoperative day. The data of the CT scans was transferred to workstation for three-dimensional reconstruction by volum rendering (VR), average intensity projection(AIP) and surface shaded display (SSD). Result : The three methods of three dimensional reconstruction provided satisfactory image of implanted electrode including the shape and the spacial relationship of the electrode in the inner ear. The insertion depth of the electrode can be evaluated directly. Moreover , each of the electrode pairs can be identified clearly. Conclusion: Postoperative evaluation of the implanted electrode with three methods of CT scans with three dimentiond reconstruction of inner ear provide more accurate image of the spacial relationship of the electrode in the cochlear canal with direct demonstration of electrode insertion depth in the cochlea.
出处 《临床耳鼻咽喉科杂志》 CSCD 北大核心 2006年第13期597-599,共3页 Journal of Clinical Otorhinolaryngology
基金 国家自然科学基金资助项目(No:30271404 30470954) "十五"国家攻关计划(No:2004BA720A18-02) 国家973项目(No:2001CB510302)
关键词 耳蜗植入 体层摄影术 X线计算机 成像 三维 Cochlear implant Tomography,X-ray computed Three-dimensioned reconstruction
  • 相关文献

参考文献5

二级参考文献23

  • 1杨仕明,张德秀,郗昕,冀飞,韩东一,杨伟炎.多导人工耳蜗植入术后耳蜗X线显像[J].中华耳科学杂志,2003,1(2):46-49. 被引量:9
  • 2[1]Beaumont D,Whyte A.Radiology of the temporal bone.Aust J Otolaryngol 1994,1:513-526.
  • 3[2]Rosenberg RA,Cohn NL,Reede DL.Radiographic imaging for the cochlear implant.Ann Oto Rhinol Larygol 1987,96:300-304.
  • 4[3]Gray RF,Evans RA,Freer CEL,et al.Radiology for cochlear implants.J Laryngol Otol 1991,106:85-88.
  • 5[4]Skinner MW,Ketten DR,Vannier MW,et al.Determin ation of the position of Nucleus cochlear implant electrodes in the inner ear.Am J Otol 1994,15:644-651.
  • 6[5]Himi T,Kataura,Sakata M,et al.Three-dimensional imaging of the temporal bone using a helical CT scan and its application in patients with cochlear implantation.J Otol Rhino Laryngol Rel Spec 1996,58:298-300.
  • 7[6]Portnoy WM,Mattucci K.Cochlear implants as a contraindication to magnetic resonance imaging.Ann Otol Rhinol laryngol 1991,100:195-197.
  • 8[7]Cohen LT,Xu J,Xu SA,Clark GM.Improved and simplified methods for specifying the position of the electrode bands of a cochlear implant array.Am J Otol 1996,17:859-865.
  • 9[8]Xu J,Xu S-A,Cohen LT,Clark GM.Cochlear view:postoperative radiography for cochlear implantation.Am J Otol 2000,21:49-56.