期刊文献+

种植支抗的稳定性研究进展 被引量:5

暂未订购
导出
摘要 种植支抗是近年来迅速发展的一项新技术,它克服了传统支抗的一些缺陷,简化了治疗过程。该文就种植支抗的稳定性问题作一综述。
出处 《口腔医学》 CAS 2006年第3期229-231,共3页 Stomatology
关键词 种植 支抗 稳定性
  • 相关文献

参考文献18

  • 1Gainsforth BL, Higley LB. A study of orthodontic anchorage possibilities in basal bone[J]. Am J Orthod Oral Surg ,1945,31(7):406-416.
  • 2Wehrbein H, Feifel H, Diedrich P. Palatal implant anchorage reinforcement of posterior teeth: A pospective study[J]. Am J Orthod Dentofacial Orthop, 1999,116(6):678-686.
  • 3Bae SM, Park HS, Kyung HM, et al. Clinical application of micro-implant anchorage[J] .J Clin Orthod, 2002,36(5) :298 - 302.
  • 4Glatzmaier J, Wehrbein H, Diedrich P. Biodegradable implants for orthodontic anchorage. A preliminary biomechancal study[J]. Eur J Orthod, 1996 ,18(5):465-469.
  • 5Gray JB,Steen ME, King GJ, et al. Studies on the efficacy of implants as orthodontic anchor-age[ J]. AM J Orthod, 1983,82(4) :311 - 317.
  • 6梁星,赵志河,唐思青,白丁,吕丹,巢永烈,丁运萍.羟基磷灰石涂层钛种植支抗的稳定性[J].华西口腔医学杂志,1998,16(2):153-155. 被引量:13
  • 7龙红月,林珠,兰泽栋,周磊.支抗种植体外形对骨界面应力分布的影响[J].中国口腔种植学杂志,2003,8(2):61-63. 被引量:11
  • 8兰泽栋,林珠,龙红月,周磊.支抗种植体直径对骨界面应力分布的影响[J].实用口腔医学杂志,2004,20(1):43-46. 被引量:20
  • 9兰泽栋,林珠,龙红月,周磊.支抗种植体长度对骨界面应力分布的影响[J].中国口腔种植学杂志,2003,8(3):112-115. 被引量:22
  • 10Wehrbein H, Diedrich P. Endosseous titanium implants during and after orthodontic load-an experimental studyin the dog [J]. Colin Oral Implants Res, 1993,4(2) : 76 - 82.

二级参考文献56

  • 1黄辉,马轩祥,张少锋.螺纹顶角角度对牙柱状螺旋根骨内种植体应力分布的影响[J].实用口腔医学杂志,1996,12(2):119-121. 被引量:25
  • 2岑远坤,毛祥彦,何佳凝,鲜苏琴.全下颌牙种植义齿及支持组织应力的三维有限元分析Ⅴ.种植体类型对覆盖种植义齿应力分布的影响[J].华西口腔医学杂志,1997,15(1):64-66. 被引量:5
  • 3[2]Meijer HJ, Starman FJ, Boman F et al. Stress distribution around dental implants: influence of superstructure, length of implants, and height of mandible. J Prosthet Dent, 1992; 68(1): 96~ 100
  • 4[3]Lum LB. A biomechanical rational for the use of short implants. J. Oral Implant, 1991; 17(2): 126~ 131
  • 5[4]Lum LB, Osier JF. Load transfer from endosteal implants to supporting bone: an analysis using statics. Part two: Axial loading. J Oral Implantol, 1992; 18(4): 349~ 353
  • 6[5]Lum LB, Osier JF. Load transfer from endosteal implants to supporting bone: an analysis using statics. Part one: Horizontal loading. J Oral Implantol, 1992; 18(4):343~ 353
  • 7[6]Goodacre CJ, Kan JY, Rungcharassaeng K et al. Clinical complications of osseointegrated implants. J Prosthet Dent, 1999 May; 81(5): 537~ 552
  • 8[7]Grunder JH. A 3-year prospective multicenter follow-up report on the immediate and delayed-immediate placement of implants. Int J Ora Maxillofac-Implants. 1999 Mar-Apr; 14(2): 210~ 216
  • 9[2]Nishihara K,Nakagiri S.Biomechanical studies on newly tailored artificial dental root.Bioed Mater Eng,1994,(3): 141~149
  • 10[4]Holmgren EP,Seckinger RJ,Kilgren LM et al.Evaluating parameters of osseointegrated dental implants using finite element analysis-a two-dimensional comparative study examining the effects of implant diameter,implant shape,and load direction.J-Oral-Implantol,1998,24(2):80~88

共引文献108

同被引文献31

引证文献5

二级引证文献22