摘要
目的:评价Rashkind法对封堵动脉导管未闭的治疗效果。材料与方法:自1994年7月至1995年9月采用Rashkind双伞法封堵动脉导管未闭(PDA)共18例。其中男6例,女12例。年龄范围6~43岁。动脉导管内径3~8mm,其中包括1例PDA结扎术后10年再通者。结果:技术成功率100%,随诊3~17个月未见残余分流及再通发生。结论:Rashkind法是一种有效的非手术治疗PDA的新方法,无并发症,无死亡。
Purpose:ToevaluatetheeficiencyofRashkindmethodfortreatingpatentductusarteriosus(PDA).Materialsandmethods:EighteenpatientswithPDAweretreatedbyRashkindmethod(double-discdevice)duringtheperiodfromJuly,1994toSeptember,1995inourhospital.Amongthe18cases,therewere6maleand12female,withmeanageof27.9years(rangingfrom6to43years).Thenarowestdiameteroftheductusrangedfrom3to8mm.Results:Theproceduresucesratewas100%,includingonecasewithreopeningPDAafter10yearsofsurgery.Folow-upstudyincludedclinicalexaminationandechocardiography.The24hoursfolow-upstudyrevealedmildresidualshuntbyechowithmildsystolicmurmurinonepatient.The3~17monthsfolow-upstudyrevealednoresidualshuntinalsuccessfulcasesandnoevidenceofreopeningPDAwasnoted.Conclusion:TheRashkindmethod(double-discdevice)isanonsurgicalefectivemethodintreatmentofPDAwithoutmorbidityormortality.