期刊文献+

冲击波压力传感器灵敏度的动态校准 被引量:13

Dynamic Calibration of Sensitivity of Shock Wave Pressure Sensor
在线阅读 下载PDF
导出
摘要 为了定期校准冲击波测试用压力传感器的灵敏度,采用阶跃压力发生器对测量气体介质的传感器灵敏度进行动态校准,产生的阶跃压力信号最高压力为7M Pa;采用水动力脉冲发生器对液体介质动态压力传感器的灵敏度进行动态校准,产生的液体脉冲压力信号最高压力幅值为140M Pa,并可由标准比对传感器准确确定幅值。结果表明,两种方法是准确可靠的,与新出厂校准的动态压力测试用传感器的灵敏度进行比较,相对误差不超过0.6%。 In order to calibrate the sensitivity of pressure sensors termly, the dynamic calibration of all sorts of pressure sensors used to measure the dynamic pressure in the medium of gas and liquid is performed by a gas step pressure calibrator with the highest pressure of 7 MPa and a hydraulic impulse calibrator with the highest pressure of 140MPa. According to the studies on the sensor characteristic, the matching between sensor and dynamic calibration device and the value trace to the source of pressure measurement, a good result is obtained. Comparing measurement result with the dynamic pressure sensitivity when leave factory, the relative error is not up to 0. 6%.
出处 《火炸药学报》 EI CAS CSCD 2006年第3期62-64,共3页 Chinese Journal of Explosives & Propellants
关键词 爆炸力学 压力传感器 灵敏度 校准 冲击波 explosion mechanics pressure sensor sensitivity calibration shock wave
  • 相关文献

参考文献6

  • 1贝克 W E..空中爆炸[M]..北京:原子能出版社,,1974....
  • 2俞统昌,郭炜,王建灵.自由大气爆炸冲击波超压测试[C]∥电子测量及仪器学术研讨会论文集,北京:电子技术应用出版社,2002:86-89.
  • 3黄正平.爆炸与冲击过程测试技术[M].北京理工大学出版社,1994..
  • 4李科杰.新编传感器技术手册[M].北京:国防工业出版社,2001.
  • 5王凤鸣.非电量电测技术[M].北京:国防工业出版社,1991.
  • 6王文襄,王晋林,李水霞,张文钊.几种高温高频压力传感器的研制与开发[J].测试技术学报,2002,16(z1):413-416. 被引量:3