期刊文献+

扬声器定心支片的顺性测试仪 被引量:3

The Measurement for Compliance of Spider and Surround of Speakers
在线阅读 下载PDF
导出
摘要 介绍了一种测量扬声器定心支片和振膜折环顺性仪器的工作原理、硬件结构和软件设置,使用该仪器在扬声器组装之前就可通过检测定心支片和振膜折环顺性得到扬声器顺性的变化曲线和确切数值,从而了解由于顺性的非线性对组装出的扬声器的影响,仪器还可用于定心支片和振膜折环元件生产的质量控制。 The principles,hardware configurations and software settings of the compliance measuring device for spiders and surrounds in loudspeakers are introduced. The compliance curve of spider and surround can be obtained before the loudspeakers are fixed, so the loudspeaker distortion which caused by the nonlinearity of compliance can be known. This measuring device is helpful in engineering design and quality control.
作者 闫秉耀
出处 《电声技术》 2006年第5期29-32,36,共5页 Audio Engineering
关键词 顺性 定心支片 振膜折环 compliance spider surround