摘要
即将颁布的国家标准《综合医院建筑设计规范》根据我国国情提出了重症监护病房定义与环境控制措施,本文从重症监护病房的定位与污染控制的思路出发,提出重症监护病房环境控制要求依据,说明有关重症监护病房条文符合我国国情,也满足环境控制要求。
China Standard "Architectural and design code for general hospital" has been revised and will be published soon.. This paper introduced briefly the intensive care unit (ICU) and its environmental control measure based on our national conditions, This paper provided HVAC system basis for the intensive care unit in view of its definition and contamina- tion control considerations. The intensive care unit could tally with our national condition and accord with the demands for the indoor environmental control.
出处
《洁净与空调技术》
2006年第2期48-51,共4页
Contamination Control & Air-Conditioning Technology
关键词
综合医院建设
通风与空调
重症监护病房
环境控制
General hospital construction Ventilation and air conditioning lintensive care unit Environmental control