摘要
介绍了900 MW机组汽机调门控制原理,分析了伺服安装调试数据。就运行中汽机调门故障产生的原因作了剖析,提出了故障消除的技术措施,积累了相关故障处理的经验。
The control principles of 900 MW steam turbine governing valves are introduced, and the data relating to the servo valve installation and debugging are analyzed. The causes of governing valve faults during operation are explained, and relevant technical measures to eliminate the faults are put forward.
出处
《华东电力》
北大核心
2006年第5期96-98,共3页
East China Electric Power
关键词
900MW机组
汽机调门控制
故障分析
900 MW unit
control of steam turbine governing valve
fault analysis