期刊文献+

小视场图像系统的非线性畸变校正方法的研究 被引量:1

Research on Nonlinear Distortion Correction Method for Computer Vision System with Small View Field
在线阅读 下载PDF
导出
摘要 分析了小视场图像系统的成像特性,针对其非线性畸变提出了基于平行光栅技术的数字图像校正方法,应用图像系统的一阶综合径向畸变数学模型,求解畸变参数和校正参数并对图像进行校正。理论分析和试验表明,本方法简单有效,校正后的畸变影响降低到0.25个像素。并对图像的畸变中心和纵横比例因子对校正的影响做了探讨。 A geometric nonlinear distortion correction method for computer vision system with small view field is presented when its character is analyzed. The distortion coefficient and correction coefficient of synthetical radio distortion with one index are solved and image is corrected easily depended on parallel raster. By the experiment, the proposed method is validated feasible and efficient, distortion effect is decreased obviously. And the effect of the image distortion center bias and scale factor ratio offset on image correction quality is discussed.
出处 《工具技术》 北大核心 2006年第5期67-70,共4页 Tool Engineering
关键词 小视场 非线性畸变 图像校正 畸变中心 纵横比例因子 small view field, nonlinear distortion, distortion correction, distortion center, scale factor ratio
  • 相关文献

参考文献6

  • 1Luca Lucchese. Geometric calibration of digital cameras through multi-view rectification. Image and Vision Computing, 2005, 23(1): 517-539
  • 2R Y Tsai. A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf cameras and lenses. IEEE Journal of Robotics and Automation, 1987(4) : 323 - 344
  • 3Ben Tordoff, David W. Murray. The impact of radial distortion on the self - calibration of rotating cameras. Computer Vision and Image Understanding, 2004, 96(1): 17- 34
  • 4Wonpil Yu. Image-based lens geometric distortion correction using minimization of average bicoherence index. Pattern Recognition, 2004, 37 (1): 1175-1187
  • 5贺俊吉,张广军,杨宪铭.基于交比不变性的镜头畸变参数标定方法[J].仪器仪表学报,2004,25(5):597-599. 被引量:53
  • 6Chantal Chatterjee, Vwani P Roychowdhury. A nonlinear Gauss-Seidel algorithm for noncoplanar and coplanar camera calibration with convergence analysis. Computer Vision and Image Understanding, 1997, 67(1) : 58 - 80

二级参考文献8

  • 1Roger Y. Tsai. A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses. IEEE. Journal of Robotics and Automation, 1987, RA-3(4):323-344.
  • 2Janne H. Geometric camera calibration using circular control points. IEEE Transactions on Pattern Analysis and Machine Intelligence, 2000, 22(10):1066-1077.
  • 3Zhengyou Zhang. A flexible new technique for camera calibration. IEEE Transactions on Pattern Analysis and Machine Intelligence, 2000, 22(11):1330-1334.
  • 4Alan M. Mclvor. Nonlinear calibration of a laser stripe profiler. Optical Engineering, 2002,41(1):205-212.
  • 5Juyang Weng. Camera calibration with distortion models and accuracy evaluation. IEEE Transactions on Pattern Analysis and Machine Intelligence, 1992, 14(10):965-980.
  • 6K. Vijayan Asari. A new approach for nonlinear distortion correction in endoscopic images based on least squares estimation. IEEE Transactions on Medical Imaging, 1999,18(4):345-354.
  • 7Warren E. Smith. Correction of distottion in endoscope images. IEEE Transactions on Medical Imaging, 1992, 11(1):117-122.
  • 8Hideaki Haneishi. A new method for distortion correction of electronic endoscope images. IEEE Transactions on Medical Imaging, 1995,14(3):548-555.

共引文献52

同被引文献6

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史