错排孔板封头对板翅式换热器流动与换热的影响 被引量:7

Effect of staggered perforated plate header on flow and heat transfer of plate-fin heat exchanger
在线阅读 下载PDF
导出
摘要 在对板翅式换热器内部物流分配研究的基础上,研究了错排孔板型结构封头对板翅式换热器出口流动与换热的影响。通过实验与工业用基本型封头对比,结果表明错排孔板型封头能够明显地改善换热器出口截面流量和温度分布的不均匀性。在Re=2 000时换热器的出口流量分布不均匀度大幅度地下降;而在Re数较大情况下,能更加显著地改善温度分布的不均匀性。 Based on the study of the flow maldistribution in plate-fin heat exchanger, the effect of staggered perforated plate header configuration on outlet flow and heat transfer in plate-fin heat exchangers was experimentally studied. Compared with the ordinary header, the experimental results show that staggered perforated plate header greatly improves the distribution of outlet flow and outlet temperature. The maldistribution of the distribution can obviously drop under Re = 2 000, and the improvement of temperature distribution is more efficient especially under higher Re number.
出处 《化学工程》 CAS CSCD 北大核心 2006年第5期12-15,共4页 Chemical Engineering(China)
基金 西安交通大学博士学位论文基金资助项目(DFXJTU2004-02) 全国首届优秀博士学位论文作者专项基金资助项目(199933)
关键词 错排孔板型封头结构 板翅式换热器 物流分配 温度分布 换热性能 staggered perforated plate header configuration temperature distribution heat exchanger efficiency plate-fin heat exchangers flow distribution
  • 相关文献

参考文献4

  • 1Mueller A C, Chiou J P. Review of various types of flow maldistribution in heat exchangers [ J ]. Heat Transfer Engineering, 1988,9 ( 2 ) : 36-50.
  • 2Ranganayakulu Ch, Seetharamu K N. The combined effects of wall longitudinal heat conduction, inlet fluid flow non-uniformity and temperature nonuniformity in compact tube-fin heat exchangers: a finite element method [ J ].International Journal of Heat and Mass Transfer, 1999,42(2) : 263-273.
  • 3张哲,厉彦忠,许箐.板翅式换热器物流分配特性的实验研究[J].西安交通大学学报,2003,37(9):920-924. 被引量:21
  • 4Wen Jian, Li Yanzhong. Study of flow distribution and its improvement on the header of plate-fin heat exchanger[J]. Cryogenics, 2004, 44(8) :823-831.

二级参考文献7

  • 1Mueller A C, Chiou J P. Review of various types of flow maldistribution in heat exchangers [J]. Heat Transfer Engineering, 1988, 9(2): 36-50.
  • 2Ranganayakulu C H, Seetharamu K N. The combined effects of longitudinal heat conduction flow nonuniformity and temperature nonuniformity in crossflow platefin heat exchanger[J]. Int Comm Heat Mass Transfer, 1999, 26: 669-678.
  • 3Lalot S, Florent P, Lang S K, et al. Flow maldistribution in heat exchangers [J]. Applied Thermal Engineering, 1999, 19:847-863.
  • 4Fleming R B. The effect of flow distribution in parallel channels of counter flow heat exchangers [J]. Adv Cryogenics Engineering, 1967, 12: 352--355.
  • 5Weimer R F, Hartaog D G. Effects of maldistribution on the performance of multistream mutltipassages heat exchangers [J]. Adv Cryogenics Engineering, 1973,18: 52-54.
  • 6Mueller A C. Effects of some types of maldistribution on the performance of heat exchangers [J]. Heat Transfer Engineering, 1987, 8(2): 75-86.
  • 7张哲,厉彦忠,焦安军.板翅式换热器封头结构的数值模拟[J].化工学报,2002,53(11):1182-1187. 被引量:33