CGMS与胰岛素泵在2型糖尿病患者血糖控制中的应用 被引量:28

暂未订购
导出
摘要 目的利用先进的动态血糖检测系统,制订治疗方案、评估胰岛素泵治疗效果。方法对20例2型糖尿病患者先进行72h血糖监测,再使用胰岛素皮下持续输注控制血糖,同时使用动态血糖检测系统评估使用前后的血糖情况。结果接受胰岛素泵治疗3d后患者的空腹血糖、三餐后、晚22:00、凌晨2:00血糖明显降低,与治疗前相比差异有统计学意义(P<0.01)。结论动态血糖检测系统与胰岛素皮下持续输注联合应用能更有效的控制血糖。
作者 流沙 陈兵
出处 《重庆医学》 CAS CSCD 2006年第10期898-898,903,共2页 Chongqing medicine
  • 相关文献

参考文献3

二级参考文献14

  • 1Vering T,Adam S,Drewer H,et al.Wearable microdialysis system for continuous in vivo monitoring of glucose.Analyst,1998,123: 1605-1609.
  • 2Cheyne EH,Cavan DA,Kerr D.Performance of a continuous glucose monitoring system during controlled hypoglycaemia in healthy volunteers.Diabetes Technol Ther,2002,4: 607-613.
  • 3Gross TM,Bode BW,Einhorn D,et al.Performance evaluation of MiniMed continuous glucose monitoring system during patient home use.Diabetes Technol Ther,2000,2:49-56.
  • 4Caplin NJ,O' Leary P,Bulsara M,et al.Subcutaneous glucose sensor values closely parrallel blood glucose during insulin-induced hypoglycaemia.Diabet Med,2003,20: 238-241.
  • 5Guerci B,Floriot M ,Bohme P,et al.Clinical performance of CGMS in type 1 diabetic patients treated by continuous subcutaneous insulin infusion using insulin analogs.Diabetes Care,2003,26: 582-589.
  • 6Boland E,Monsod T,Delucia M,et al.Limitations of conventional methods of self-monitoring of blood glucose: lessons learned from 3 days of continuous glucose sensing in pediatric patients with type 1 diabetes.Diabetes Care,2001,24:1858-1862.
  • 7Chico A,Vidal-Rios P,Subira M,et al.The continuous glucose monitoring system is useful for detecting unrecognized hypoglycemias in patients with type 1 and type 2 diabetes but is not better than frequent capillary glucose measurements for improving metabo
  • 8Kessler L,Passemard R,Oberholzer J,et al.Reduction of blood glucose variability in type 1 diabetic patients treated by pancreatic islet transplantation: interest of continuous glucose monitoring.Diabetes Care,2002,25: 2256-2262.
  • 9Lourido J,Ederoth P,Sundvall N,et al.Correlation between blood glucose concentration and glucose concentration in subcutaneous adipose tissue evaluated with microdialysis during intensive care.Scand J Clin Lab Invest,2002,62: 285-292.
  • 10Tiessen RG,Rhemrev-Boom MM,Korf J,et al.Glucose gradient differences in subcutaneous tissue of healthy volunteers assessed with ultroslow-microdialysis and a nanolitre glucose sensor.Life Sci,2002,70:2457-2466.

共引文献70

同被引文献228

引证文献28

二级引证文献142

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部