摘要 介绍了一种基于Labview的消光式椭偏仪光学测量系统,用于进行透明薄膜厚度的精确测量。研究并推导出消光式椭偏仪光学系统的数学模型及椭偏参数的计算公式。在理论研究的基础上,基于虚拟仪器设计技术,开发了信号采集、传输电路和编写测量软件,设计了椭偏仪的自动控制测量系统。通过对SiO2薄膜的测试,验证了仪器具有良好的可靠性和重复性,薄膜厚度误差小于100,折射率误差小于0.01。 The paper introduces a light elimination type ellipsometer optical system based on Labview, which can realize accurate measurement of film thickness. The mathematical model of elimination type ellipsometer optical system and the formula of elliptical parameter are researched and deduced. By theory research, the circuit of signal acquiring and transforming and the measurement soft is developed. Based on virtual instrumentation technology, automatic control measurement system of ellipsometer is designed. Through the testing of SiO2 film, it has been proved that the reliability and repetition of the instrument are favorable. The measurement error of the film thickness is less than 100 A and the measurement error of the refractivity rate is less than 0. 01.
出处 《传感技术学报》 EI CAS CSCD 北大核心 2006年第2期432-435,共4页 Chinese Journal of Sensors and Actuators
基金 国家自然科学基金资助项目(49974010)
关键词 椭偏仪 消光法 虚拟仪器 LABVIEW ellipsometer elimination virtual instrumentation Labview
  • 相关文献

参考文献5

二级参考文献11

  • 1朱惠贤,罗晋生.0.5~2.0eV红外光自动椭偏谱仪的研制与应用[J].西安交通大学学报,1993,27(3):69-74. 被引量:3
  • 2张克奇 严义损.提高旋转检偏器式椭偏仪准确度的方法[J].光学学报,1988,8(3):228-234.
  • 3[4](美)Suleiman am英Lalani and Ramesh Chandak著曾湘宁译.ActiveX编程技术与技巧.电子工业出版社.1999
  • 4莫党,物理学报,1980年,29卷,5期,673页
  • 5王志刚,山东大学学报,1987年,22卷,1期,86页
  • 6Aspnes D E,Studua A A.High precision scanning ellipsometer[J].Appl. Opt.,1975,14 (1) :220~228.
  • 7Zaghloul A R M,Azzam R M.Single-element rotating polarizerellipsometer [J]: PSI meter. Surf. Sci.,1980,96 (1) :168~173.
  • 8Woollam J A,Snyder P G,Rost M C.Variable angle spectroscopic ellipsometry : a nondestructive characterization technique for ultrathin and multilayter materials [J] . Thin SolidFilm, 1998,166 (1) :317~323.
  • 9Azzam R M A , Bashara N M.Ellipsometry and polarizedlight [M] North-Holland. Amsterdam, 1977:269~416.
  • 10朱德瑞,赖天树,李秋俊,莫党.高精度自动化椭圆偏振光谱仪[J].中山大学学报(自然科学版),1997,36(4):31-36. 被引量:17

共引文献19

同被引文献17

  • 1徐平,张勇,侯占强,江平.基于MS3110的差分电容检测方法研究及其电磁兼容性设计[J].仪表技术与传感器,2008(5):60-61. 被引量:6
  • 2杨华勇,周伟林,李智忠,孙崇峰,胡永明.窄带激光器调谐的光纤光栅波长移位解调[J].半导体光电,2005,26(1):75-78. 被引量:5
  • 3吴礼刚,任仁,朱三根,龚海梅.基于LabVIEW的低温半导体器件温度循环系统[J].半导体光电,2006,27(4):445-447. 被引量:2
  • 4Wu Ligang, Liu Dafu, Huang Yimin, et al. A feasible thermal cycle screening system for cryogenic semiconductor components[J]. Proc. of SPIE, 2005, 5640:85-93.
  • 5牛昱光.单片机原理与接口技术[M].北京:电子工业出版社,2009.
  • 6Jong-Kwan Woo, Hyunjoong Lee, Sungho Ahn, et al. A High-Resolution and Fast-Conversion Readout Circuit for Differential Ca- pacitive Sensors [ C ]//Thomas Biichner, Ramalingam Sridhar, Andrew Marshall, eds. Proc. of the 23rd IEEE International System on Chip Conference( SOCC ). Las Vegas : SOCC ,2010.44-47.
  • 7德国acam公司.PICOCAP数据手册DB-PCap01-0301_eVO.4[EB/OL].http://www.acam.de,2011-5-13.
  • 8Ho-Young Park, Sang-Hyeok Yang, Suki Kim, et al. A Touch Sensor Readout Circuit Using Awitched-Capacitor Charge Pump [ J ]. IEICE Electronics Express ,2012,9 ( 13 ) : 1090-1095.
  • 9Ebrahim Ghafar Zadeh, Mohamad Sawan. High Accuracy Differential Capacitive Circuit for Bioparticles Sensing Applications [C]//Wen-Ben Jone, eds. Proc. of the 48th IEEE Midwest Symposium on Circuits and Systems ( MWSCAS ) : Covington: MWSCAS ,2005. 1362-1365.
  • 10Alexander A Trusov, Andrei M Shkel. A Novel Capacitive Detection Scheme With Inherent Self-Calibration [ J ]. Journal of Microelectromechanical Systems,2007,16 ( 6 ) : 1324-1333.

引证文献2

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部